HP Brocade 8/12c HP StorageWorks B-series Data Center Fabric Manager Professio - Page 14
notification is disabled when he tries to enable an
View all HP Brocade 8/12c manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
Closed defect summary Solution Port selection button does not get enabled for inactive FCIP tunnel in performance port picker Symptom-Suppose a tunnel is present which was active some time back and later becomes inactive then the user will not be able generate graph for inactive tunnel as the port selector is disabled for inactive FCIP tunnels in the performance port picker. Fixed in DCFM 10.1.0 Workaround-If the user wants to generate the graph for all the types[active and inactive tunnels], the user will have to select FCIP from the historical wizard from the "From" drop-down list and then generate a graph. But for real time the user cannot select in active tunnels. Zoning report showing zone name twice when zone is part of active zone config. Symptom-When user generates report with active zone config, the active zone appears twice in the Report with Active=Yes and Active=No values. Fixed in DCFM 10.1.0 DCFM Professional, disable backup, nl migrate to enterprise, open options-backup, close, invalid error message. Symptom-A confusing error message when using the options dialog after migration. Even though the backup is disabled the path is invalid and must contain a valid path. Fixed in DCFM 10.1.0 Workaround-Enter a valid backup directory, even if backup is disabled. Error message is not displayed when Trace Route nl operation fails due to McDATA fabric mode. Fixed in DCFM 10.1.0 Workaround-Trace Route summary dialog shows information in Fcping tab and blank Forward and Reverse Route tabs instead of showing an error message when McDATA fabric mode is set. Informational message is not appearing when the user tries to enable notification from the user dialog, when it is disabled from the main dialog(Monitor > Event Notification > Email). Symptom-User will not get warned that the notification is disabled when he tries to enable an event notification from the user management dialog. Fixed in DCFM 10.1.0 The connection between the FOS and EOS switches is not shown on launching DCFM Client for the first time after a migration from EFCM to DCFM. Symptom-On launching DCFM Client for the first time after a migration from EFCM to DCFM, the connection between the FOS and the EOS switch is not displayed in the Connectivity map. Fixed in DCFM 10.1.0 Workaround-Close and relaunch the DCFM Client. Changing server IP after DCFM installation created multiple issues. Symptom-During installation, the option 'any' was chosen in the ipconfiguration screen. After installing DCFM, on changing the server machine IP, it is observed that the DCFM client is not launching. The Client login window itself was not shown on trying to launch the DCFM client. The DCFM server services were still running. The client failed to launch even after restarting the server. Fixed in DCFM 10.1.0 14