HP Carrier-grade cc3300 UserÆs Guide and Technical UserÆs Gu - Page 14
Environmental Specifications
View all HP Carrier-grade cc3300 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 14 highlights
HP cc3300 Carrier Grade Server Product Guide Environmental Specifications The cc3300 Carrier Grade Server has been tested to the environmental specifications as indicated in Table 2. All testing has been performed per procedures defined in Bellcore GR-63-CORE NEBS Physical Protection, Bellcore GR-3580 NEBS Criteria Levels, Bellcore GR-1089-CORE EMC and Electrical Safety - Generic Criteria for Network Telecommunications Equipment. . Table 2. Environmental Specifications Summary Environment Temperature operating Specification 10 °C to 35 °C (50° F to 95° F) Temperature non-operating -40 °C to 70 °C (-104° F to 158° F) Altitude 0 to 1,800 m (0 to 5,905 ft) Humidity non-operating 95%, non-condensing at temperatures of 23° C (73° F) to 40° C (104° F) Vibration operating Swept sine survey at an acceleration amplitude of 0.1 g from 5 to 100 Hz and back to 5 Hz at a rate of 0.1 octave/minute, 90 minutes per axis on all three axes as per Bellcore GR-63-CORE standards. Vibration non-operating Swept sine survey at an acceleration amplitude of 0.5 g from 5 to 50 Hz at a rate of 0.1 octaves/minute, and an acceleration amplitude of 3.0g from 50 to 500 Hz at a rate of 0.25 octaves/minute, on all three axes as per Bellcore GR-63-CORE standard. 2.2 Grms, 10 minutes per axis on all three axes. Shock operating Half-sine 2 G, 11 ms pulse, 100 pulses in each direction, on each of the three axes. Shock non-operating Trapezoidal, 25 G, 170-inch/sec delta V, three drops in each direction, on each of the three axes. Electrostatic discharge (ESD) Tested to ESD levels up to 15 kilovolts (kV) air discharge and up to 8 kV contact discharge without physical damage. Acoustic Sound pressure: < 55 dBA at ambient temperatures < 28°C measured at bystander positions in operating mode. Sound power: < 6.5 BA at ambient temperatures < 28°C in operating mode. Power Maximum current at 100 VAC Maximum current at 120 VAC Maximum current at 230 VAC Does the input current differ at 50 to 60Hz (if yes, input the highest value) Maximum peak inrush current Time to decay to 25% of maximum peak Time duration to return to nominal Total harmonic distortion (voltage) Power factor KVA rating Heat dissipation BTU's per hour 1.8 Amps 1.5 Amps 0.8 Amps No 17.7 Amps 0.3 Seconds 6 Seconds 0.12% 0.87 0.19 KVA 190 Watts 649 BTU/hr 14 Chassis Description