Modified System Messages, An attempt was made to assign a primary VLAN to an 802.1x port

Page 29 highlights

Documentation Updates Error Message SCHED-3-UNEXPECTEDEVENT: [traceback] [process information] Process received unknown event (maj [hex], min [hex]) Explanation A process did not handle an event. The first [hex] is the major event number, and the second [hex] is the minor event number, both of which allow you to identify the event that occurred. Recommended Action Copy the message exactly as it appears on the console or in the system log. Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to look for similar reported problems. If you still require assistance, open a case with the TAC, or contact your Cisco technical support representative, and provide the representative with the gathered information. Modified System Messages Error Message DOT1X-5-RESULT_OVERRIDE: Authentication result overridden for client ([chars]) on Interface [chars] AuditSessionID [chars] Explanation The authentication result was overridden. The first [chars] is the client ID, the second [chars] is the interface, and the third [chars] is the session ID. Recommended Action No action is required. Error Message DOT1X_SWITCH-5-ERR_INVALID_PRIMARY_VLAN: Attempt to assign primary VLAN [dec] to 802.1x port [chars] AuditSessionID [chars] Explanation An attempt was made to assign a primary VLAN to an 802.1x port, which is not allowed. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID. Recommended Action Use a different VLAN. Note This message applies to switches running the IP base image. Error Message DOT1X_SWITCH-5-ERR_INVALID_SEC_VLAN: Attempt to assign invalid secondary VLAN [dec] to PVLAN host 802.1x port [chars] AuditSessionID [chars] Explanation An attempt was made to assign a nonsecondary VLAN to a private VLAN host 802.1x port. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID. Recommended Action Change the port mode so that it is no longer a PVLAN host port, or use a valid secondary VLAN. Note This message applies to switches running the IP base image. OL-22861-04 Release Notes for the Cisco Catalyst Blade Switch 3020 for HP, Cisco IOS Release 12.2(55)SE and Later 29

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34

29
Release Notes for the Cisco Catalyst Blade Switch 3020 for HP, Cisco IOS Release 12.2(55)SE and Later
OL-22861-04
Documentation Updates
Error Message
SCHED-3-UNEXPECTEDEVENT: [traceback] [process information] Process
received unknown event (maj [hex], min [hex])
Explanation
A process did not handle an event. The first [hex] is the major event number, and the
second [hex] is the minor event number, both of which allow you to identify the event that occurred.
Recommended Action
Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to look
for similar reported problems. If you still require assistance, open a case with the TAC, or contact
your Cisco technical support representative, and provide the representative with the gathered
information.
Modified System Messages
Error Message
DOT1X-5-RESULT_OVERRIDE: Authentication result overridden for client
([chars]) on Interface [chars] AuditSessionID [chars]
Explanation
The authentication result was overridden. The first [chars] is the client ID, the second
[chars] is the interface, and the third [chars] is the session ID.
Recommended Action
No action is required.
Error Message
DOT1X_SWITCH-5-ERR_INVALID_PRIMARY_VLAN: Attempt to assign primary
VLAN [dec] to 802.1x port [chars] AuditSessionID [chars]
Explanation
An attempt was made to assign a primary VLAN to an 802.1x port, which is not allowed.
[dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action
Use a different VLAN.
Note
This message applies to switches running the IP base image.
Error Message
DOT1X_SWITCH-5-ERR_INVALID_SEC_VLAN: Attempt to assign invalid
secondary VLAN [dec] to PVLAN host 802.1x port [chars] AuditSessionID [chars]
Explanation
An attempt was made to assign a nonsecondary VLAN to a private VLAN host 802.1x
port. [dec] is the VLAN, the first [chars] is the port, and the second [chars] is the session ID.
Recommended Action
Change the port mode so that it is no longer a PVLAN host port, or use a valid