HP Designjet 815mfp HP Designjet 4200 Scanner - User Guide - Page 65

tell me about the scanner insertion slot

Page 65 highlights

see also maintenance procedures on page 24 tell me about the scanner insertion slot You can change the insertion slot height from 2 to 16 mm (0.08 to 0.63 inches). The Normal position (Step 0: 2 mm/0.08 in) is detected by a sensor in the scanner. The insertion slot is marked with a measurement ruler for inches and millimeters. The ruler corresponds to right side aligned original loading. Just below the ruler are marked common standard sizes that help guide you with optional centered loading. The loading method, right-side or centered, can be selected from your scanner software. The scan area width measured in standard units (inches or millimeters) is also set from the software. The required setting for an original drawing can be measured with the original inserted into the scanner by using the ruler printed on top of the insertion slot. Then, you just enter your measurement in the width setting box in the current scanner application's media size setup dialogs. To change the insertion slot height, see how do I change the insertion slot height? on page 8. hp designjet 815mfp & scanner 4200 59

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110

hp designjet 815mfp & scanner 4200
59
see also
maintenance procedures
on page 24
tell me about the scanner insertion slot
You can change the insertion slot height from 2 to 16 mm (0.08 to
0.63 inches). The Normal position (Step 0: 2 mm/0.08 in) is
detected by a sensor in the scanner.
The insertion slot is marked with a measurement ruler for inches and
millimeters. The ruler corresponds to right side aligned original
loading. Just below the ruler are marked common standard sizes
that help guide you with optional centered loading.
The loading method, right-side or centered, can be selected from
your scanner software. The scan area width measured in standard
units (inches or millimeters) is also set from the software.
The required setting for an original drawing can be measured with
the original inserted into the scanner by using the ruler printed on
top of the insertion slot. Then, you just enter your measurement in
the width setting box in the current scanner application
s media size
setup dialogs. To change the insertion slot height, see
how do I
change the insertion slot height?
on page 8.