HP Indigo WS6600 Dripping Prevention and ITM Heating Hood Service -- CA393-101 - Page 41

HP Indigo WS6600 Manual

Page 41 highlights

6. Check the cleaning station wiper and verify the 2mm spacer exist inside the wiper assembly. If not, order a new wiper assembly (refer to the parts catalog). Figure 3-1 2 mm spacer inside cleaning station wiper assembly 7. Check that the cleaning station return hose O ring & V seal ring are installed properly and are not damaged. Figure 3-2 Cleaning station inlet pipe with V-seal and O-ring 1 V-seal 2 O-ring Figure 3-3 V-seal on cleaning station inlet pipe 1 Rear wall of press 2 Cleaning station inlet pipe 3 V-seal - 0905-1593 38 Chapter 3 Troubleshooting

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

6.
Check the cleaning station wiper and verify the 2mm spacer exist inside the wiper assembly. If not,
order a new wiper assembly (refer to the parts catalog).
Figure 3-1
2 mm spacer inside cleaning station wiper assembly
7.
Check that the cleaning station return hose O ring & V seal ring are installed properly and are not
damaged.
Figure 3-2
Cleaning station inlet pipe with V-seal and O-ring
1
V-seal
2
O-ring
Figure 3-3
V-seal on cleaning station inlet pipe
1
Rear wall of press
3
V-seal – 0905-1593
2
Cleaning station inlet pipe
38
Chapter 3
Troubleshooting