HP Indigo WS6600 Dripping Prevention and ITM Heating Hood Service -- CA393-101 - Page 62
External Hood air knife blower, IO_ECN_EXIT_BLANKET_SPEED, EBV air knife blower,
View all HP Indigo WS6600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 62 highlights
Figure 3-41 External Hood air knife blower 4. After measuring, reconnect the 2"pipe to the blower. 5. Verify that there is air flow to the hood duct. Measuring the EBV air knife blower air flow Folloow these steps to measure the EBV air knife blower air flow. 1. Disconnect the 2" pipe from the blower: 2. In Systab Editor, set IO_ECN_EXIT_BLANKET_SPEED to 1023. 3. Place the Anemometer at the outlet duct, as shown below. NOTE: Place the vane far from the outlet and then move it closer to the outlet to avoid impact on the wings. Air velocity should be 29 ± 2 m/sec. Figure 3-42 EBV air knife blower Measuring the utility cabinet outlet air flow Follow these steps to measure the utility cabinet outlet air flow. Measuring the EBV air knife blower air flow 59