HP Indigo WS6600 Dripping Prevention and ITM Heating Hood Service -- CA393-101 - Page 45

damaged, replace the catch tray. If it is wet, remove the tray

Page 45 highlights

12. Using an external conductivity meter, check the conductivity rate of the imaging oil in the reservoir. The conductivity should be ~0mp. If the conductivity exceeds 40 mp, replace the imaging oil filters and the imaging oil in the reservoir. Clean the reservoir before refilling it. 13. Check that the isolation layer on the cleaning station catch tray is in good condition. If it is damaged, replace the catch tray. If it is wet, remove the tray, and dry out the imaging oil. 14. Verify that the blower ducts are clean with no obstructions. Check for, and remove any pieces of substrate at the external heater suction and EBV duct. Check all units as show in figures Press in Shutdown on page 37 to Press in Shutdown on page 37. Figure 3-11 External Heater (E/H) duct connector panel 1 Verify that the fitting pipe is connected correctly at the rear. Figure 3-12 EBV upper section assembly 1 Verify that the divider is in place. 42 Chapter 3 Troubleshooting

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

12.
Using an external conductivity meter, check the conductivity rate of the imaging oil in the reservoir.
The conductivity should be ~0mp. If the conductivity exceeds 40 mp, replace the imaging oil filters
and the imaging oil in the reservoir. Clean the reservoir before refilling it.
13.
Check that the isolation layer on the cleaning station catch tray is in good condition. If it is
damaged, replace the catch tray. If it is wet, remove the tray, and dry out the imaging oil.
14.
Verify that the blower ducts are clean with no obstructions. Check for, and remove any pieces of
substrate at the external heater suction and EBV duct. Check all units as show in figures
Press in
Shutdown
on page
37
to
Press in Shutdown
on page
37
.
Figure 3-11
External Heater (E/H) duct connector panel
1
Verify that the fitting pipe is connected correctly at the rear.
Figure 3-12
EBV upper section assembly
1
Verify that the divider is in place.
42
Chapter 3
Troubleshooting