HP Indigo WS6600 Dripping Prevention and ITM Heating Hood Service -- CA393-101 - Page 56
Press in Standby, Systab > EngineConfigTopic > FeedFanModulationInstalled
View all HP Indigo WS6600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 56 highlights
a. Go to Systab > EngineConfigTopic > FeedFanModulationInstalled. The value should be True, meaning that the FFM is installed. Figure 3-30 Systab showing FFM installed b. Go to Systab > bypassTopic > FeedFanModulation. The value should be False. meaning that the FFM is not bypassed. Figure 3-31 Systab showing FFM not bypassed Press in Standby Follow these steps for dripping correction procedures when press in standby. 1. Put the press in Standby status. Press in Standby 53
a.
Go to
Systab > EngineConfigTopic > FeedFanModulationInstalled
. The value should be
True
,
meaning that the FFM is installed.
Figure 3-30
Systab showing FFM installed
b.
Go to
Systab > bypassTopic > FeedFanModulation
. The value should be
False
. meaning that
the FFM is not bypassed.
Figure 3-31
Systab showing FFM not bypassed
Press in Standby
Follow these steps for dripping correction procedures when press in standby.
1.
Put the press in Standby status.
Press in Standby
53