HP Indigo WS6600 Dripping Prevention and ITM Heating Hood Service -- CA393-101 - Page 52
Calibration Procedures > Imaging Oil Flow > Cleaning Station Flow Calibration Wizard
View all HP Indigo WS6600 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 52 highlights
Figure 3-24 ITM hood - Check isolation material 19. Turn on the press. 20. In the SysTab editior, check if the cleaning station pump voltage value is above 2500 (imgingoiltopic > imoCleanstationCtrlVoltage > IO_clean_station_control_voltage), and that the Cleaning Station Flow Calibration wizard did not succeed to reduce the flow to give a voltage value of approximately 2300. If this is so, the following components may be clogged: ● Cleaning station heat exchanger ● Cleaning station pump NOTE: For presses with the DFS installed - if the pump voltage value is near 2700, the DFS Automatic Calibration wizard may fail. 21. Run the Cleaning Station Flow Calibration wizard. Select Print Care > Maintenance > Subsystem Calibration Procedures > Imaging Oil Flow > Cleaning Station Flow Calibration Wizard. NOTE: For tips on how to get the most out of the wizard, refer to Calibrating cleaning station imaging oil flow (CA393-04840). If the wizard does not work, perform manual Cleaning Station Flow Calibration: NOTE: Two people are needed for this task a. Verify that the press is in Standby. b. Verify that the PIP drum is disengaged. Press in Shutdown 49