HP Indigo WS6600 Dripping Prevention and ITM Heating Hood Service -- CA393-101 - Page 52

Calibration Procedures > Imaging Oil Flow > Cleaning Station Flow Calibration Wizard

Page 52 highlights

Figure 3-24 ITM hood - Check isolation material 19. Turn on the press. 20. In the SysTab editior, check if the cleaning station pump voltage value is above 2500 (imgingoiltopic > imoCleanstationCtrlVoltage > IO_clean_station_control_voltage), and that the Cleaning Station Flow Calibration wizard did not succeed to reduce the flow to give a voltage value of approximately 2300. If this is so, the following components may be clogged: ● Cleaning station heat exchanger ● Cleaning station pump NOTE: For presses with the DFS installed - if the pump voltage value is near 2700, the DFS Automatic Calibration wizard may fail. 21. Run the Cleaning Station Flow Calibration wizard. Select Print Care > Maintenance > Subsystem Calibration Procedures > Imaging Oil Flow > Cleaning Station Flow Calibration Wizard. NOTE: For tips on how to get the most out of the wizard, refer to Calibrating cleaning station imaging oil flow (CA393-04840). If the wizard does not work, perform manual Cleaning Station Flow Calibration: NOTE: Two people are needed for this task a. Verify that the press is in Standby. b. Verify that the PIP drum is disengaged. Press in Shutdown 49

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72

Figure 3-24
ITM hood — Check isolation material
19.
Turn on the press.
20.
In the SysTab editior, check if the cleaning station pump voltage value is above 2500 (
imgingoiltopic
> imoCleanstationCtrlVoltage > IO_clean_station_control_voltage
), and that the Cleaning Station
Flow Calibration wizard did not succeed to reduce the flow to give a voltage value of approximately
2300. If this is so, the following components may be clogged:
Cleaning station heat exchanger
Cleaning station pump
NOTE:
For presses with the DFS installed — if the pump voltage value is near 2700, the DFS
Automatic Calibration wizard may fail.
21.
Run the
Cleaning Station Flow Calibration
wizard. Select
Print Care > Maintenance > Subsystem
Calibration Procedures > Imaging Oil Flow > Cleaning Station Flow Calibration Wizard
.
NOTE:
For tips on how to get the most out of the wizard, refer to
Calibrating cleaning station
imaging oil flow
(CA393-04840).
If the wizard does not work, perform manual Cleaning Station Flow Calibration:
NOTE:
Two people are needed for this task
a.
Verify that the press is in Standby.
b.
Verify that the PIP drum is disengaged.
Press in Shutdown
49