HP LH4r HP Netserver Service Handbook, Volume 1 - Low End - Page 116

HP Rail Kit, Fibre Channel Hub

Page 116 highlights

Descriptions * Fibre Channel HBA * Fibre Channel Hub * Fibre Channel Optical GBIC * Fibre Channel Copper GBIC * Cable, Optical, 100 meters * Cable, Copper, 3 meters * Cable, Copper, 5 meters * Cable, Copper, 10 meters * Cable, Copper, 30 meters * Cable, Copper, 50 meters * HP Rail Kit, Fibre Channel Hub Specifications Replacement D6977-63001 D6976-63001 D6975-63001 D6976-63002 D6981-63001 D6978-63001 D6979-63001 D7080-63001 D7081-63001 D6980-63001 D6976-63009 Exchange D6977-69001 D6976-69001 Temperature Operating Non-operating Humidity (non-condensing) Operating Non-operating Altitude Operating Non-Operating Weight and Dimensions Height Width Depth Weight, chassis fully loaded Weight, chassis empty Power Requirements Input voltage range Frequency 5° to 35° C (40° to 95° F) -40° to 65° C (-40° to -140° F) 20% to 80% relative humidity Maximum 95% relative humidity 3,046 m (10,000 ft.) 12,200 m (40,000 ft.) 13.2 cm (5.19 in.) 46.36 cm (18.25 in.) 71.76 cm (28.25 in.) 37.7 kg (83 lb.) 15.9 kg (35 lb.) 90-264 VAC 47-63 Hz. Typical AC input requirements for fully loaded configuration (73% of power supply capability): 110

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126

110
Descriptions
Replacement
Exchange
*
Fibre Channel HBA
D6977-63001
D6977-69001
*
Fibre Channel Hub
D6976-63001
D6976-69001
*
Fibre Channel Optical GBIC
D6975-63001
*
Fibre Channel Copper GBIC
D6976-63002
*
Cable, Optical, 100 meters
D6981-63001
*
Cable, Copper, 3 meters
D6978-63001
*
Cable, Copper, 5 meters
D6979-63001
*
Cable, Copper, 10 meters
D7080-63001
*
Cable, Copper, 30 meters
D7081-63001
*
Cable, Copper, 50 meters
D6980-63001
*
HP Rail Kit, Fibre Channel Hub
D6976-63009
Specifications
Temperature
Operating
to 35°
C (40°
to 95°
F)
Non-operating
-40° to 65° C (-40°
to -140°
F)
Humidity (non-condensing)
Operating
20% to 80% relative humidity
Non-operating
Maximum
95% relative humidity
Altitude
Operating
3,046 m (10,000 ft.)
Non-Operating
12,200 m (40,000 ft.)
Weight and Dimensions
Height
13.2 cm (5.19 in.)
Width
46.36 cm (18.25 in.)
Depth
71.76 cm (28.25 in.)
Weight, chassis fully
loaded
37.7 kg (83 lb.)
Weight, chassis empty
15.9 kg (35 lb.)
Power Requirements
Input voltage range
90-264 VAC
Frequency
47-63 Hz.
Typical AC input requirements for fully loaded configuration (73% of power supply capability):