HP LH4r HP Netserver Service Handbook, Volume 1 - Low End - Page 89
Weight and Dimensions
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 89 highlights
Non-operating Maximum 95% relative humidity Altitude Operating Non-operating 3,046 m (10,000 ft) 12,200 m (40,000 ft) Weight and Dimensions Height Width Depth Weight, fully loaded Weight, without drives 13.3 cm (5.19 in) 48.2 cm (18.97 in) 55.88 cm (22 in) 36.6 kg (80.5 lb) 26.8 kg (58.9 lb) Power Supply Specifications Power supply input voltage Power supply output Redundant switching with the following power-factor auto-range AC input: 100 to 127 VAC ~ 6.0 A at 50/60 Hz 220 to 240 VAC ~ 3.15 A at 50/60 Hz 194 W continuous 230 W peak 83
83
Non-operating
Maximum
95% relative humidity
Altitude
Operating
3,046 m (10,000 ft)
Non-operating
12,200 m (40,000 ft)
Weight and Dimensions
Height
13.3 cm (5.19 in)
Width
48.2 cm (18.97 in)
Depth
55.88 cm (22 in)
Weight, fully loaded
36.6 kg (80.5 lb)
Weight, without drives
26.8 kg (58.9 lb)
Power Supply Specifications
Power supply input voltage
Redundant switching with the following power-factor auto-range AC
input:
100 to 127 VAC ~ 6.0 A at 50/60 Hz
220 to 240 VAC ~ 3.15 A at 50/60 Hz
Power supply output
194 W continuous
230 W peak