HP LH4r HP Netserver Service Handbook, Volume 1 - Low End - Page 55
Specifications
View all HP LH4r manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
Power Cords Country Australia United States Denmark Europe HP Part Number 8120-1369 8120-1751 8120-2956 8120-1689 Country UK Japan Switzerland Cables Only the following HP cables are supported: Cable Cable, Flexible disk Cable, SCSI Cable, IDE/CD-ROM Fan Part Number 5182-3509 5182-9323 5182-3508 5182-9379 Specifications HP Part Number 8120-1351 8120-4753 8120-2104 Operating Environment Non-operating altitude: Operating altitude: Non-operating temperature (storage): Operating temperature: Non-operating humidity: Operating humidity: Acoustic emission: 40,000 feet (12,200 meters) 10,000 feet (3048 meters) -40 degrees to +70 degrees C (-40 degrees to +158 degrees F) +5 degrees to +35 degrees C 8 to 80% relative humidity 15 % to 80% relative humidity Sound level (LpA): < 45 dB(A) NOTE Procedure for recovery from moisture condensation: let the product stabilize at room temperature for 15 minutes then power on. 49