HP LaserJet 4100 HP PCL/PJL reference (PCL 5 Printer Language) - Technical Ref - Page 242
No Parameters, Related Commands, Group, Condition, Printer Response, Parameter, Format
View all HP LaserJet 4100 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 242 highlights
Table 22-25 Related Commands LA, Line Attributes LT, Line Type Group The Line and Fill Attributes Group Table 22-26 POSSIBLE ERROR CONDITIONS: Condition Printer Response sum of gap parameters equals zero ignores command a gap is negative ignores command index = 0 or|index| > 8 ignores command WU, Pen Width Unit Selection This command specifies how the width parameter of the Pen Width (PW) command is interpreted (whether metric or relative units). WU type[;] or WU [;] Parameter Format type clamped integer Functional Range 0 to 1 Default 0 (metric) Since using WU, with or without parameters, defaults all pen widths, send the WU command before a PW command (which sets a new pen width). z No Parameters - Defaults type parameter to 0 (metric) and all pen widths to 0.35 mm. 22-46 The Line and Fill Attributes Group EN