ProLiant ML330e/ML330 Server Maintenance and Service Guide Fourth Edition (March 2001) Part Number 174623-004 Spare Part Number 176670-001 Compaq Computer Corporation - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 2
Pentium are trademarks of Intel Corporation in the United States and other countries. All other product names mentioned herein may be trademarks of their respective companies. Compaq or additional warranty. Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Fourth Edition (March - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 3
Compartment (ProLiant ML330e Server 2-10 SCSI Hard Drive Compartment (ProLiant ML330 Server 2-12 Hard Drives ...2-14 Power Switch...2-15 Fan ...2-17 Cable Routing Diagrams 2-18 Processor with Heatsink 2-21 Memory Modules 2-23 Removing a Memory Module 2-25 Expansion Slots ...2-26 Server Feature - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 4
iv Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Removal and Replacement Procedures continued Expansion Board Guide 2-28 System Board ...2-29 Power Supply ...2-30 Replacing a Battery 2-31 Replacing the System Board Battery 2-31 Replacing the Server Feature Board Battery 2-33 - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 5
Guide This maintenance and service guide is a troubleshooting guide that can be used for reference when servicing the Compaq ProLiant ML330e/ML330 server. WARNING: To reduce the risk of personal injury from electric shock and hazardous energy levels, only authorized service or specific instructions. - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 6
vi Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Compaq Technician Notes WARNING: Only authorized technicians trained by Compaq can attempt to repair this equipment. All troubleshooting and repair procedures are detailed to allow only subassembly/module-level repair. Because of - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 7
are available: User documentation Compaq Service Quick Reference Guide Service training guides Compaq service advisories and bulletins Compaq QuickFind™ information services Compaq Insight Manager software Integrated Management Log The ProLiant ML330e/ML330 server includes an integrated, nonvolatile - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 8
1 Chapter Illustrated Parts Catalog This chapter provides the illustrated parts breakdown and spare parts lists for the Compaq ProLiant™ ML330e/ML330 server with an Intel Pentium III processor and a 133-MHz system bus. See Table 1-1 and Table 1-2 for the names of referenced spare parts. - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 9
1-2 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Mechanical Parts Exploded View 3a 3b 2 4c 5a Figure 1-1. Mechanical parts exploded view 4b 1 4a - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 10
ML330e server ProLiant ML330 server Panel access left/right a) Hood panel (right) b) Access panel (left) Miscellaneous Hardware kit a) Hard drive compartment b) Removable drive tray c) Expansion board knockout Miscellaneous plastics kit a) Expansion board guide b) Rubber bumpers* c) Removable - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 11
1-4 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide System Components Exploded View 13 9 10 14 15 16a 11 12 15 Figure 1-2. System components exploded view 6a 7 8a - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 12
9 Fan 10 PC 133-MHz ECC Registered SDRAM DIMM a) 64-MB* b) 128-MB* c) 256-MB* d) 512-MB* 11 12 13 *Not shown Boards System board ProLiant ML330e server ProLiant ML330 server Server Feature Board ProLiant ML330e server ProLiant ML330 server Power CE Mark-compliant power supply Spare - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 13
1-6 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Table 1-2 System Components Spare Parts List continued Item Description 14 Pentium III processor a) 667/133 with heatsink* b) 733/133 with heatsink* c) 800/133 with heatsink* (ProLiant ML330e and ML330) d) 866/133 with heatsink* - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 14
for the Compaq ProLiant ML330e/ML330 server. Run the diagnostics program to verify that all components properly operate. To service the ProLiant ML330e/ML330 server, you might need the following: Torx T-15 screwdriver Phillips screwdriver From the Compaq SmartStart™ and Support Software CD: Array - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 15
2-2 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Electrostatic Discharge Information An electrostatic discharge (ESD) can damage static-sensitive devices or microcircuitry. Proper packaging and grounding techniques are necessary precautions to prevent damage. To prevent - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 16
exists. WARNING: To reduce the risk of injury from a hot component, allow the surface to cool before touching it. These symbols, on power supplies or systems, indicate that the equipment is supplied by multiple sources of power. WARNING: To reduce the risk of injury from electric shock, remove all - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 17
with a regulating uninterruptible power supply (UPS). This device protects the hardware from damage caused by power surges and voltage spikes, and keeps the system in operation during a power failure. CAUTION: The ProLiant ML330e/ML330 server must always be operated with system unit covers on - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 18
injury and to prevent damage to the equipment, before removing the front bezel, make sure that the server is powered down, all cables are disconnected from the back of the server, and the power cord is disconnected from the grounded (earthed) AC outlet. To remove the front bezel: 1. Complete the - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 19
2-6 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Access Panel WARNING: To reduce the risk of personal injury from hot surfaces, allow the internal system components to cool before touching them. WARNING: To reduce the risk of personal injury and to prevent damage to the - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 20
Removal and Replacement Procedures 2-7 Storage Devices The ProLiant ML330e/ML330 server ships standard with seven drive bays, five of which are available. Figure 2-3 shows the location of the storage devices. Table 2-1 shows the corresponding drive bay descriptions. 1 2 3 4 5 6 7 Figure 2-3. - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 21
2-8 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Bezel Blanks To remove a bezel blank from the front bezel: WARNING: To reduce the risk of personal injury and to prevent damage to the equipment, before removing the front bezel, make sure that the server is powered down, all - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 22
injury and to prevent damage to the equipment, before removing the access panel, make sure that the server is powered down, all cables are disconnected from the back of the server, and the power cord is disconnected from the grounded (earthed) AC outlet. NOTE: The drive trays in the removable media - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 23
2-10 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide ATA Hard Drive Compartment (ProLiant ML330e Server) To remove an ATA hard drive compartment from the ProLiant ML330e server: 1. Complete the preparation procedures. See "Preparation Procedures" earlier in this chapter. 2. Remove - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 24
Removal and Replacement Procedures 2-11 5. Remove the three shipping screws , squeeze the two spring clips , and then pull the drive compartment from the chassis . 2 2 3 1 1 Figure 2-7. Removing an ATA hard drive compartment To replace an ATA hard drive compartment, reverse steps 2 through 5. - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 25
2-12 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide SCSI Hard Drive Compartment (ProLiant ML330 Server) To remove a SCSI hard drive compartment from the ProLiant ML330 server: 1. Complete the preparation procedures. See "Preparation Procedures" earlier in this chapter. 2. Remove - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 26
Removal and Replacement Procedures 2-13 5. Remove the three shipping screws , squeeze the two spring clips , and then pull the drive compartment from the chassis . 2 2 3 1 1 Figure 2-9. Removing a SCSI hard drive compartment To replace a SCSI hard drive compartment, reverse steps 2 through 5. - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 27
2-14 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Hard Drives To remove a hard drive from 3. Remove the access panel. See "Access Panel" earlier in this chapter. 4. Disconnect all the power and data cables from the back of all drives on the hard drive compartment. 5. Remove the - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 28
Removal and Replacement Procedures 2-15 Power Switch IMPORTANT: To completely remove all power from the system, you must disconnect the power cord from the server. To remove the power switch: 1. Complete the preparation procedures. See "Preparation Procedures" earlier in this chapter. 2. Remove the - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 29
2-16 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide 5. From the front of the chassis, squeeze the sides of the power switch to disengage the two retainer clips from the chassis , and then gently remove the power switch from the chassis . 6. Also from the front of the chassis, - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 30
panel. See "Access Panel" earlier in this chapter. 4. Disconnect the fan power cable from the system board fan connector . 5. Use a Phillips screwdriver to remove the four mounting screws from the rear of the server . 6. Pull the fan out and away from the chassis . 2 3 1 Figure 2-13. Removing the - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 31
2-18 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Cable Routing Diagrams Figure 2-14 through Figure 2-18 show cable routing diagrams for the ProLiant ML330e/ML330 server. 1 2 Figure 2-14. Diskette drive cable and IDE CD-ROM drive cable routing Table 2-2 Diskette Drive Cable - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 32
Removal and Replacement Procedures 2-19 Figure 2-15. Server Management Information Cable (SMIC) routing (ProLiant ML330e server) Figure 2-16. Server Management Information Cable (SMIC) routing (ProLiant ML330 server) - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 33
2-20 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Figure 2-17. ATA cable routing (ProLiant ML330e server) Figure 2-18. Integrated Wide Ultra2 SCSI cable routing (ProLiant ML330 server) - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 34
To reduce the risk of personal injury from hot surfaces, allow the internal system components to cool before touching them. 1. Complete the preparation procedures. See " "Access Panel" earlier in this chapter. 4. Unplug the processor fan from the system board. Figure 2-19. Unplugging the processor - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 35
2-22 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide 5. Press down and release the heatsink retainer clip to disengage one side from the processor socket . 6. Unhook the opposite side of the heatsink retainer clip from the processor socket , and then lift the heatsink/fan assembly - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 36
Removal and Replacement Procedures 2-23 Memory Modules The ProLiant ML330e/ML330 server supports 64-, 128-, 256-, or 512-MB PC 133-MHz Registered error checking and correcting (ECC) synchronous dynamic random access memory (SDRAM) dual inline memory modules (DIMMs). CAUTION: Electrostatic discharge - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 37
2-24 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide NOTE: Memory modules do not need to be installed in pairs and can be installed in any available socket. 1 2 3 4 Figure 2-21. Memory module socket locations Table 2-3 Memory Module Socket Locations Item Description Socket 1 - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 38
. See "Front Bezel" earlier in this chapter. 3. Remove the access panel. See "Access Panel" earlier in this chapter. 4. Press outward on both latches of the memory module socket at the same time . This step releases the DIMM and pushes it partially out of the socket. 5. Lift the - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 39
2-26 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Expansion Slots 1 2 3 4 5 6 Figure 2-23. Expansion slot locations Table 2-4 Expansion Slots Item Description 64-bit PCI (half-length) 64-bit PCI 32-bit PCI (Server Feature Board) 32-bit PCI 32-bit PCI 32-bit PCI Slot - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 40
5. Remove the screw securing the Server Feature Board to the chassis , and then pull the Server Feature Board out of the server . 1 2 Figure 2-24. Removing the Server Feature Board NOTE: The Server Feature Board is located only in slot 3. To replace the Server Feature Board, reverse steps 2 through - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 41
2-28 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Expansion Board Guide To remove the expansion board guide: 1. chapter. 4. Remove all expansion boards supported by the board guide. 5. Push in the four locking tabs , and then pull the guide back and away from the chassis . - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 42
) before beginning any installation procedure. See "Electrostatic Discharge Information" earlier in this chapter for more information. To remove the system board: 1. Complete the preparation procedures. See "Preparation Procedures" earlier in this chapter. 2. Remove the front bezel. See "Front Bezel - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 43
2-30 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Power Supply To remove the power supply: WARNING: To reduce the risk of electric shock or damage to the equipment: Unplug the power cord before removing the power supply from the server. Install the power supply before connecting - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 44
Removal and Replacement Procedures 2-31 Replacing a Battery The ProLiant ML330e/ML330 server has nonvolatile memory, which requires a battery to retain system information. There is a battery on the system board and a battery on the Server Feature Board. These batteries are required to maintain - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 45
2-32 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide 4. Locate the battery on the system board, and then slide the battery out of the holder. 5. Slide the replacement battery into the proper position with the positive (+) side up. Figure 2-28. - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 46
Positive (+) polarity must be positioned up. 7. Replace the Server Feature Board, front panel, and bezel. 8. Connect the server and power up. 9. For the ProLiant ML330 server, run the BIOS Setup utility to reconfigure your system. 10. For the ProLiant ML330e server, run the RBSU to reconfigure your - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 47
3 Chapter Diagnostics Tools This chapter provides an overview of the software and firmware diagnostics tools available for the Compaq ProLiant ML330e/ML330 server. - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 48
must be accessed when a system configuration error is detected during Power-On Self-Test (POST). For a complete list of POST error messages, see the Compaq Servers Troubleshooting Guide. Compaq Diagnostics software is also available on the Compaq SmartStart and Support Software CD. A Diagnostics - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 49
Compaq systems that support Compaq array controllers. The main functions of ADU are to collect all possible information about the array controllers in the system and to generate a list of detected problems. Integrated Management Log BIOS Setup utility for the ProLiant ML330 server A log of system - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 50
3-4 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Table 3-1 Diagnostics Tools continued Tool What it is ROM Based Setup Utility (RBSU) for the ProLiant ML330e server Utility used to configure some hardware installed in or connected to the server. Specifically, it can: - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 51
Diagnostics Tools 3-5 For More Information For detailed information about each of these diagnostics tools, see the Compaq Servers Troubleshooting Guide on the documentation CD. For the most recent version of this guide, go to the Compaq website: http://www.compaq.com - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 52
4 Chapter Connectors, Switches, and LED Indicators This chapter contains illustrations and tables identifying connectors, switches, and LED locations on the rear panel, Server Feature Board, and system board for the Compaq ProLiant ML330e/ML330 server. - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 53
4-2 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Connectors This section contains graphics and tables identifying connector locations on the system board, rear panel, and Server Feature Board for the Compaq ProLiant ML330e/ML330 server. System Board Components 15 14 16 13 - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 54
64-bit PCI slot 2 64-bit PCI slot 1 (half-length) Battery System fan connector Processor Serial port connector B Parallel port connector Serial port connector A USB ports (ProLiant ML330e server only) Item Description Mouse connector Keyboard connector Power supply connector Diskette drive - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 55
4-4 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Rear Panel Connectors 1 2 3 4 5 6 7 8 9 Figure 4-2. Rear panel connectors Table 4-2 Rear Panel Connectors Item Description Item Description Power cord Serial ports Voltage selector switch Parallel port Mouse RJ-45 - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 56
server) Table 4-3 Server Feature Board Components (ProLiant ML330e Server) Item Description ATA channel connector Server Management Information Cable (SMIC) connector Server Feature Board configuration switch Replaceable lithium coin cell battery (CR2032) RJ-45 Ethernet connector for NIC - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 57
4-6 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Server Feature Board Components (ProLiant ML330 Server) 2 1 9 3 8 4 7 6 5 Figure 4-4. Server Feature Board components (ProLiant ML330 server) Table 4-4 Server Feature Board Components (ProLiant ML330 Server) Item - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 58
, Switches, and LED Indicators 4-7 Switches This section contains graphics and tables showing switch locations on the ProLiant ML330e/ML330 server system board and Server Feature Board. Reserved Processor Switch Settings (SW1) on 12 3 4 Figure 4-5. Reserved processor switch settings (SW1) Switch - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 59
4-8 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide System Configuration Switch Settings (SW2) on 12 3 4 Figure 4-6. System configuration switch settings (SW2) Switch 1 2 3 4 Table 4-6 System Configuration Switch Settings (SW2) Default Off Function Clear/set up password Off - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 60
is disabled IMPORTANT: Positions 2 through 8 are reserved for Compaq authorized service providers only. Do not change these switches from the indicated default settings. NOTE: For information on troubleshooting video problems, refer to "Video Problems" in the Compaq Servers Troubleshooting Guide. - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 61
4-10 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Voltage Regulator Switch Set the voltage regulator switch to either 115 volts or 230 volts, as appropriate for your location. 115 230 Figure 4-8. Voltage regulator switch location - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 62
controller status LEDs System Status LEDs 1 2 3 Figure 4-9. System status power button LEDs Table 4-8 System Status LEDs Item Power button Power status Hard drive activity status Status System on System on, AC power OK. Do not remove power from system. System off, no AC power Drive being - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 63
4-12 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Network Controller LEDs 1 23 Figure 4-10. Network controller LEDs Table 4-9 Network Controller LEDs Item Description Status Condition Speed Off 10Base-T 10-Mbps (10Base-T Ethernet) On - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 64
chapter provides specifications for the Compaq ProLiant ML330e/ML330 server. The following specifications are provided: System Unit Memory 1.44-MB Diskette Drive IDE CD-ROM Drive Wide Ultra2 SCSI Hard Drives for the ProLiant ML330 Server ATA Hard Drives for the ProLiant ML330e Server Integrated 10 - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 65
5-2 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide System Unit Table 5-1 System Unit Specifications Dimensions Height Width Depth Weight International input requirements Rated input voltage Rated input frequency Rated input current U.S. input requirements Rated input voltage - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 66
Table 5-2 Memory Specifications 64-, 128-, 256-, and 512-MB, and 1-GB PC 133-MHz ECC Registered SDRAM DIMMs 1.44-MB Diskette Drive Table 5-3 1.44-MB Diskette Drive Specifications Size LED indicators (front panel) Read/write capacity per diskette (high/low density) Drives supported Drive height - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 67
5-4 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide IDE CD-ROM Drive Applicable disk Track pitch Cache/buffer Startup time Stop time Table 5-4 IDE CD-ROM Specifications CD-ROM (modes 1 and 2); mixed mode (audio and data combined); CD-DA; Photo CD (single- and multiple-session), - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 68
25 nm Divergence angle 53.5° ± 1.5° Output power 0.14 mW Operating conditions Temperature 5°C to 45°C (41°F to 113°F) Humidity 5% to 90% (10% to 80%) ATA Hard Drives (ProLiant ML330e Server) Table 5-5 ATA Hard Drive (ProLiant ML330e Server) Specifications Capacity Height Width Interface - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 69
5-6 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Wide Ultra2 SCSI Hard Drives (ProLiant ML330 Server) Table 5-6 Wide Ultra2 SCSI Hard Drive (ProLiant ML330 Server) Specifications Capacity Height Width Interface Transfer rate synchronous (max) Seek time (typical, including - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 70
Table 5-7 Integrated 10/100 Wake on LAN NIC Specifications Network interface Compatibility Data transfer method Network transfer rate Connector I/O address and interrupt Compliance OS support (ProLiant ML330 server) OS support (ProLiant ML330e server) 10Base-T/100Base-TX IEEE 802.2, 802.3, 802 - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 71
5-8 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Integrated Ultra ATA 100 Controller Table 5-9 Integrated Ultra ATA 100 Controller Specifications Protocol Drives supported Data transfer method Maximum transfer rate per PCI Bus (peak) ATA channel transfer rate ATA connectors - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 72
memory modules 2-23 overheating vi power fluctuations 2-4 power supply 2-30 proper cooling 2-4 ventilation clearances vi CD-ROM drive cable routing, illustrated 2-18 CD-ROM drive, part number 1-5 CE Mark-compliant power supply See power supply chassis, part number 1-3 clamps, part number 1-3 Compaq - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 73
Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide 2-9 replacing 2-9 drivers, installing 3-3 E guide part number 1-3 removing 2-28 removing, illustrated 2-28 replacing 2-28 expansion board knockout, part number 1-3 expansion slot locations 2-26 locations, illustrated 2-26 F fan - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 74
board guide, removing 2-28 expansion slot, locations 2-26 fan, removing 2-17 front bezel, removing 2-5 hard drive, removing 2-14 IDE CD-ROM drive, cable routing 2-18 Integrated Wide Ultra2 SCSI (ProLiant ML330 server), cable routing 2-20 LEDs, removing 2-16 mechanical parts, exploded view 1-2 memory - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 75
4 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide K keyboard, part number 1-6 kits country 1-6 hardware 1-3 plastics, miscellaneous 1-3 power cable 1-6 return 1-6 signal cable 1-6 L labels, symbols on equipment 2-3 LEDs described 4-11 network controller status 4-11 removing 2-16 - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 76
switch settings (SW1) 4-9 illustrated 4-9 Server Feature Board components ProLiant ML330 Server 4-6 ProLiant ML330 server, illustrated 4-6 ProLiant ML330e Server 4-5 ProLiant ML330e server, illustrated 4-5 Server Management Information Cable See SMIC server specifications 5-1 signal cable kit, part - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 77
6 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide specifications CD-ROM drive access times 5-4 capacity 5-4 data transfer rate 5-4 dimensions 5-4 laser parameters 5-5 operating conditions 5-5 rotational speed 5-4 startup time 5-4 stop time 5-4 weight 5-4 diskette drive access - HP ProLiant ML330e | Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 78
11 System Unit Specifications 5-2 Wide Ultra2 SCSI Hard Drive (ProLiant ML330 Server) Specifications 5-6 technical support, telephone numbers vii technician notes, warning vi, 2-4 telephone numbers Compaq authorized resellers vii technical support vii telephone symbol 2-3 tools required for service
ProLiant ML330e/ML330 Server
Maintenance and Service Guide
Fourth Edition (March 2001)
Part Number 174623-004
Spare Part Number 176670-001
Compaq Computer Corporation