HP ProLiant ML330e Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 65

System Unit, Table 5-1, System Unit Specifications

Page 65 highlights

5-2 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide System Unit Table 5-1 System Unit Specifications Dimensions Height Width Depth Weight International input requirements Rated input voltage Rated input frequency Rated input current U.S. input requirements Rated input voltage Rated input frequency Rated input current Power supply output power Rated steady state power BTUs for tower model Temperature range Operating Nonoperating Relative humidity (noncondensing) Operating Nonoperating Acoustic noise Idle (hard drives spinning) Operating (random seeks to hard drives) 42.86 mm (16.88 in) 19.05 mm (7.5 in) 50.8 mm (20 in) 10.1 kg (26 lb) weight approximate, depending upon options 180 VAC to 264 VAC 50 Hz to 60 Hz 3 A 90 VAC to 132 VAC 50 Hz to 60 Hz 6 A CE Mark-compliant 1,560 10°C to 35°C/50°F to 93°F -30°C to 60°C /-22°F to 140°F 20% to 80% 5% to 90% 6 NPEL (Bels)/43 AVERAGE SPL (dba) 6.1 NPEL (Bels)/44 AVERAGE SPL (dba)

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

5-2
Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide
System Unit
Table 5-1
System Unit Specifications
Dimensions
Height
42.86 mm (16.88 in)
Width
19.05 mm (7.5 in)
Depth
50.8 mm (20 in)
Weight
10.1 kg (26 lb) weight approximate, depending
upon options
International input requirements
Rated input voltage
180 VAC to 264 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
3 A
U.S. input requirements
Rated input voltage
90 VAC to 132 VAC
Rated input frequency
50 Hz to 60 Hz
Rated input current
6 A
Power supply output power
Rated steady state power
CE Mark-compliant
BTUs for tower model
1,560
Temperature range
Operating
10°C to 35°C/50°F to 93°F
Nonoperating
-30°C to 60°C /-22°F to 140°F
Relative humidity (noncondensing)
Operating
20% to 80%
Nonoperating
5% to 90%
Acoustic noise
Idle (hard drives spinning)
6 NPEL (Bels)/43 AVERAGE SPL (dba)