HP ProLiant ML330e Compaq ProLiant ML330e/ ML330 Server Maintenance and Servic - Page 19

Access Panel

Page 19 highlights

2-6 Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide Access Panel WARNING: To reduce the risk of personal injury from hot surfaces, allow the internal system components to cool before touching them. WARNING: To reduce the risk of personal injury and to prevent damage to the equipment, before removing the access panel, make sure that the server is powered down, all cables are disconnected from the back of the server, and the power cord is disconnected from the grounded (earthed) AC outlet. CAUTION: Do not operate the server while the large access panel is removed. This panel is an integral part of the cooling system, and removing the panel while the system is running may adversely affect data integrity. To remove the access panel: 1. Perform the preparation procedures. See "Preparation Procedures" earlier in this chapter. 2. Remove the front bezel. See "Front Bezel" earlier in this chapter. 3. Remove the screw located on the left side of the front chassis . 4. Slide the access panel forward, pull from the top of the access panel, and then lift the panel from the chassis . 2 1 Figure 2-2. Removing the access panel NOTE: Turn the access panel over to locate the System Configuration Label. This label provides information about the system board on your ProLiant ML330e/ML330 server. To replace the access panel, reverse steps 2 through 4.

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78

2-6
Compaq ProLiant ML330e/ML330 Server Maintenance and Service Guide
Access Panel
WARNING:
To reduce the risk of personal injury from hot surfaces, allow the internal system
components to cool before touching them.
WARNING:
To reduce the risk of personal injury and to prevent damage to the equipment,
before removing the access panel, make sure that the server is powered down, all cables are
disconnected from the back of the server, and the power cord is disconnected from the
grounded (earthed) AC outlet.
CAUTION:
Do not operate the server while the large access panel is removed. This panel is an
integral part of the cooling system, and removing the panel while the system is running may
adversely affect data integrity.
To remove the access panel:
1. Perform the preparation procedures. See
Preparation Procedures
earlier in this chapter.
2. Remove the front bezel. See
Front Bezel
earlier in this chapter.
3. Remove the screw located on the left side of the front chassis
.
4. Slide the access panel forward, pull from the top of the access panel, and then lift the
panel from the chassis
.