HP StorageWorks 8/40 Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 274
FSS-1004, Severity, Message, Probable Cause, Recommended, Action, memShow, haSyncStart, supportFtp
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 274 highlights
33 FSS-1004 Severity WARNING FSS-1004 Message , [FSS-1004], ,, ERROR, , Memory shortage Probable Cause Indicates that the system ran out of memory. Recommended Action Run the memShow command to view memory usage. Run the haSyncStart command if this is a dual-CP system, or reboot the switch if it is a nonbladed system. If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the supportSave command and contact your switch service provider. Severity ERROR FSS-1005 Message , [FSS-1005], ,, WARNING, , FSS read failure Probable Cause Indicates that the read system call to the Fabric OS state synchronization (FSS) device failed. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity WARNING FSS-1006 Message , [FSS-1006], ,, WARNING, , No FSS message available Probable Cause Indicates that data is not available on the Fabric OS state synchronization (FSS) device. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity WARNING FSS-1007 Message , [FSS-1007], ,, CRITICAL, , : Faulty Ethernet connection. 216 Fabric OS Message Reference 53-1001157-01