HP StorageWorks 8/40 Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 445
PS System Messages, PS-1000
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 445 highlights
Chapter PS System Messages 66 PS-1000 Message , [PS-1000], , FFDC, CRITICAL, , Failed to initialize Advanced Performance Monitoring. Probable Cause Indicates an unexpected software error has occurred in Advanced Performance Monitoring. The Performance Monitor has failed to initialize. Recommended The CP should reboot (or fail over) automatically. If it does not, reboot or power cycle the switch to Action reinitiate the firmware. Severity CRITICAL PS-1001 Message , [PS-1001], ,, INFO, , Advanced Performance Monitoring configuration updated due to change in PID format Probable Cause Indicates the PID format was changed. Recommended No action is required. Refer to the Fabric OS Administrator's Guide for more information about the Action PID format. Severity INFO PS-1002 Message , [PS-1002], ,, INFO, , Failed to initialize the tracing system for Advanced Performance Monitoring. Probable Cause Indicates an unexpected software error has occurred in Advanced Performance Monitoring. The Performance Monitor tracing system has failed to initialize. Recommended Tracing will not be available for Advanced Performance Monitoring, but other functions should Action function normally. To retry activating tracing, reboot (or fail over) the CP. Severity INFO PS-1003 Message , [PS-1003], ,, WARNING, , Failed to set end-to-end monitoring mask on ISL ports. Fabric OS Message Reference 387 53-1001157-01