HP StorageWorks 8/40 Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 557
SULB-1032, Recommended, Action, Severity, Message, Probable Cause, firmwareDownload, firmwareShow
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 557 highlights
80 SULB-1032 Recommended Wait for the operation to complete. Action Severity WARNING SULB-1032 Message , [SULB-1032], , AUDIT, WARNING, , Relocating an internal firmware image on the CP. Probable Cause Indicates the switch has started a firmware download to the co-CPU. Recommended Wait for the operation to complete. Action Severity WARNING SULB-1033 Message , [SULB-1033], , AUDIT, WARNING, , Switch has completed relocating the internal firmware image. Probable Cause Indicates the firmwareDownload process has completed normally on the switch. Recommended Run the firmwareShow command to verify the firmware versions. Run the switchShow command to Action make sure the switch is enabled. Severity WARNING SULB-1034 Message , [SULB-1034], , AUDIT, ERROR, , Firmwaredownload timed out. Probable Cause Indicates there may be an error caused by the switch initialization issue after the internal image is relocated. It may also be caused by the internal Ethernet issue or by persistent storage failure. Recommended Action Reboot the switch. This will cause the internal image to be relocated again. Use the firmwareDownloadStatus command to monitor the progress. If the problem persists, contact your switch service provider. Severity ERROR SULB-1035 Message , [SULB-1035], , AUDIT, ERROR, , An error has occurred during relocation of the internal image. Fabric OS Message Reference 499 53-1001157-01