HP StorageWorks 8/40 Brocade Fabric OS Message Reference guide v6.2.0 (53-1001 - Page 592
ZONE-1022, Message, Probable Cause, Recommended, Action, Severity, supportFtp, supportSave, cfgSave
View all HP StorageWorks 8/40 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 592 highlights
92 ZONE-1022 ZONE-1022 Message , [ZONE-1022], ,, INFO, , The effective configuration has changed to . Probable Cause Indicates the effective zone configuration has changed to the name displayed. Recommended Verify this zone configuration change was done on purpose. If the new effective zone configuration Action is correct, no action is necessary. Severity INFO ZONE-1023 Message , [ZONE-1023], ,, INFO, , Switch connected to port () is busy. Retry zone merge. Probable Cause Indicates the switch is retrying the merge operation. This usually occurs if the switch on the other side of the port is busy. Recommended If the message persists, run supportFtp (as needed) to set up automatic FTP transfers; then run the Action supportSave command and contact your switch service provider. Severity INFO ZONE-1024 Message , [ZONE-1024], ,, INFO, , . Probable Cause Indicates the cfgSave command ran successfully. The is "cfgSave completes successfully." Recommended No action is required. Action Severity INFO ZONE-1026 Message , [ZONE-1026], ,, INFO, , port Out of CAM entries. Probable Cause Indicates the total number of S_ID entries while creating or adding a zone group exceeds the limit. Recommended If hardware zoning enforcement is preferred, edit the zoning database to have zoned PIDs for that Action port. Severity INFO 534 Fabric OS Message Reference 53-1001157-01