HP Visualize c3000 hp Visualize b1000 and c3000 workstations owner's guide (a5 - Page 89
Ultra2 Wide Low-Voltage Differential SCSI Bus, Length
View all HP Visualize c3000 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 89 highlights
NOTE SCSI Connections SCSI Bus Length Constraints Ultra2 Wide Low-Voltage Differential SCSI Bus Length The maximum cable length for an Ultra2 Wide Low-Voltage Differential SCSI bus is 12 meters. The HP VISUALIZE B Class and C Class system uses 1 meter of this maximum cable length internally. This means that up to 11 meters of cable can be used for connecting external Ultra2 Wide Low-Voltage Differential SCSI devices to this workstation. When calculating the total Ultra2 Wide Low-Voltage Differential SCSI cable/bus/trace length used externally, remember to account for cables connecting external devices together as well as the bus length internal to those devices. Chapter 4 89
Chapter 4
89
SCSI Connections
SCSI Bus Length Constraints
Ultra2 Wide Low-Voltage Differential SCSI Bus
Length
The maximum cable length for an Ultra2 Wide Low-Voltage Differential
SCSI bus is 12 meters. The HP V
ISUALIZE
B Class and C Class system
uses 1 meter of this maximum cable length internally. This means that
up to 11 meters of cable can be used for connecting external Ultra2 Wide
Low-Voltage Differential SCSI devices to this workstation.
NOTE
When calculating the total Ultra2 Wide Low-Voltage Differential SCSI
cable/bus/trace length used externally, remember to account for cables
connecting external devices together as well as the bus length internal to
those devices.