HP rp3440 Internal Cabling Guide for HP Smart Array Controllers - Page 20

Dual Partition Configurations

Page 20 highlights

Cabling for the HP Integrity rx7620 Server Recabling for RAID Dual Partition Configurations Figure 2-5 shows the correct cabling for a dual partition configuration, as viewed from the front of the server. Figure 2-5 Smart Array 6402 or 6404 Controller Card with Dual Partition Cabling Setting up RAID Cabling on the Top Right and Top Left Hot Plug Hard Drives To set up the RAID cabling on the top right and top left hot plug hard drives, do the following, from the front of the server: Step 1. Confirm the HP Smart Array 6402 or 6404 controller card is installed in PCI slot 1-7. Refer to the HP Smart Array 5300 User Guide. Step 2. Retrieve two cables from the cable kit (A7027-63001). Step 3. Identify the new cables using the colored cable ties which are also contained in the cable kit (for each cable, use two of the same color, one on each end). Step 4. Plug the end of the cables with the pull-tab into the SCSI connector port A1 on the Smart Array card. Repeat for SCSI connector port A2. Step 5. Route the other end of the cables out through the left hand side of the server. Step 6. Route the cables towards the front of the server and over to the mass storage connectors. Step 7. Unplug the existing SCSI ribbon cables for the top left and top right HDDs (use the label behind the connectors to determine which connector goes to which drive). Step 8. Plug the new cable from the Smart Array card Port A2 (closest to the bracket) into the mass storage connector for the top left drive. 16 Chapter 2

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

Cabling for the HP Integrity rx7620 Server
Recabling for RAID
Chapter 2
16
Dual Partition Configurations
Figure 2-5 shows the correct cabling for a dual partition configuration, as viewed from the front of the server.
Figure 2-5
Smart Array 6402 or 6404 Controller Card with Dual Partition Cabling
Setting up RAID Cabling on the Top Right and Top Left Hot Plug Hard Drives
To set up the RAID cabling on the top right and top left hot plug hard drives, do the following, from the front
of the server:
Step 1.
Confirm the HP Smart Array 6402 or 6404 controller card is installed in PCI slot 1-7. Refer to the
HP Smart Array 5300 User Guide
.
Step 2.
Retrieve two cables from the cable kit (A7027-63001).
Step 3.
Identify the new cables using the colored cable ties which are also contained in the cable kit (for
each cable, use two of the same color, one on each end).
Step 4.
Plug the end of the cables with the pull-tab into the SCSI connector port A1 on the Smart Array
card. Repeat for SCSI connector port A2.
Step 5.
Route the other end of the cables out through the left hand side of the server.
Step 6.
Route the cables towards the front of the server and over to the mass storage connectors.
Step 7.
Unplug the existing SCSI ribbon cables for the top left and top right HDDs (use the label behind
the connectors to determine which connector goes to which drive).
Step 8.
Plug the new cable from the Smart Array card Port A2 (closest to the bracket) into the mass storage
connector for the top left drive.