HP rp3440 Internal Cabling Guide for HP Smart Array Controllers - Page 50

Removing the Power Connectors, Disconnecting the iLO Manageability Card

Page 50 highlights

Cabling for the HP Integrity rx2620 and rx2600 Servers Recabling for RAID Step 6. Use a T-15 torx driver to unscrew the two power connector mounting screws and remove the power connectors from the back of the system. See Figure 5-12. Figure 5-12 Removing the Power Connectors Step 7. Disconnect the iLO Manageability card connector (orange) as shown in Figure 5-13. Figure 5-13Disconnecting the iLO Manageability Card Connector Step 8. Remove the two screws holding the iLO Manageability Card to the system board. The screws are located on the far left and right sides of the card when viewed from the back of the server chassis. Step 9. Remove the two connector-screws for the 25-Pin Management Port located on the right end of the card (holding it against the back of the server chassis). Step 10. Remove the card by grasping it by the edges and pulling it out (see Figure 5-14). Place the card on the anti-static bag that the controller card came in. Figure 5-14 Removing the iLO Manageability Card 46 Chapter 5

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

Cabling for the HP Integrity rx2620 and rx2600 Servers
Recabling for RAID
Chapter 5
46
Step 6.
Use a T-15 torx driver to unscrew the two power connector mounting screws and remove the power
connectors from the back of the system. See Figure 5-12.
Figure 5-12 Removing the Power Connectors
Step 7.
Disconnect the iLO Manageability card connector (orange) as shown in Figure 5-13.
Figure 5-13Disconnecting the iLO Manageability Card Connector
Step 8.
Remove the two screws holding the iLO Manageability Card to the system board. The screws are
located on the far left and right sides of the card when viewed from the back of the server chassis.
Step 9.
Remove the two connector-screws for the 25-Pin Management Port located on the right end of the
card (holding it against the back of the server chassis).
Step 10.
Remove the card by grasping it by the edges and pulling it out (see Figure 5-14). Place the card on
the anti-static bag that the controller card came in.
Figure 5-14 Removing the iLO Manageability Card