Hitachi HTS541010G9AT00 Specifications - Page 112
Idle Immediate E1h/95h
UPC - 000061425019
View all Hitachi HTS541010G9AT00 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 112 highlights
12.10 Idle Immediate (E1h/95h) Table 63: Idle Immediate command (E1h/95h) Command Block Output Registers Register 7 6 5 4 3 2 1 0 Data Feature Sector Count LBA Low LBA Mid LBA High Device 1-1 ----- Command 1 1 1 0 0 0 0 1 76 CRC UNC 00 Error Register 54 3 2 1 0 0 IDN 0 ABT T0N AMN 00 0 V 0 0 Command Block Input Registers Register 7 6 5 4 3 2 1 0 Data Error see below Sector Count LBA Low LBA Mid LBA High Device Status see below Status Register 7 654 3 2 1 0 BSY RDY DF DSC DRQ COR IDX ERR 0 V0V - 0 - V The Idle Immediate command causes the device to enter Performance Idle mode. The device is spun up to operating speed. If the device is already spinning, the spin up sequence is not executed. During Idle mode the device is spinning and ready to respond to the host commands immediately. The Idle Immediate command will not affect the auto power down time-out parameter. Travelstar 5K100 (Serial ATA) Hard Disk Drive Specification 100