English MAINTENANCE NOTE: The information contained in this Manual is designed to assist you in the safe maintenance of the Nailer. Some illustrations in this Manual may show details or attachments that differ from those on your own Nailer. MAINTENANCE AND INSPECTION Read section titled "SAFETY" (pages 5 - 12). DANGER ⅷ Never use and test in presence of flammable liquids or gases. ⅷ Keep away from ignition source. ⅷ No smoking. Cloth CAUTION ⅷ Check that the nail feeder slides smoothly by pulling it with finger. If not smooth, nails can be driven at an irregular angle and hurt someone. 2. Storing WARNING ⅷ Remove fuel cell, battery and all nails from Nailer when: 1) doing maintenance and inspection; and 2) clearing a jam. 1. Inspecting the magazine 1 REMOVE FUEL CELL and BATTERY. 2 Clean the magazine. Remove dust and wooden chips which may have accumulated in the magazine. Lubricate it with Hitachi Gas tool lubricant. DANGER ⅷ Store Nailer properly with fuel cell and battery removed. ⅷ The fuel cell is an aerosol dispensers with flammable contents. 120°F MAX ⅷ When not in use, (50°C) the Nailer, fuel cell and battery should be stored in tool case and in a dry place. ⅷ Store indoors at temperature below 120°F (50°C). 31