IBM 86626RY Hardware Maintenance Manual - Page 304
DIMM Location J1, VRM 6 or VRM 5
UPC - 087944501879
View all IBM 86626RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 304 highlights
Error Code/Symptom 089-XXX-001 (Failed Microprocessor test) 089-XXX-002 (Failed Microprocessor test) 089-XXX-003 (Failed Microprocessor test) 089-XXX-004 (Failed Microprocessor test) 165-XXX-000 (Failed System Board test) 180-XXX-000 (Diagnostics LED failure) 180-XXX-001 (Failed information LED panel test) 180-XXX-002 (Failed Diagnostics LED Panel test) 180-XXX-003 (Failed System Board LED test) 180-XXX-004 (Failed Processor Board LED test) 180-XXX-005 (Failed SCSI Backplane LED test) 201-XXX-001 (Failed Memory test, see"Memory settings" on page 30 ) 201-XXX-002 (Failed Memory test, see"Memory settings" on page 30 ) 201-XXX-003 (Failed Memory test, see"Memory settings" on page 30 ) FRU/Action 1. VRM 1 or VRM 2 2. Microprocessor CPU 1 1. VRM 3 or VRM 2 2. Microprocessor CPU 2 1. VRM 4 or VRM 5 2. Microprocessor CPU 3 1. VRM 6 or VRM 5 2. Microprocessor CPU 4 1. System Board Before replacing the system board, ensure that system board jumper J51 is not installed (the default) when the error occurs. 2. Processor Board 3. Power Backplane 4. Hot-Swap Drive Backplane 1. Run Diagnostic LED test for the failing LED 1. Information LED Panel 2. Power Switch Assembly 1. Diagnostics LED Panel 2. Power Switch Assembly 1. Run hot-swap PCI latch test in Other Devices under Extended Tests 2. System Board 1. Processor Board 2. System Board 1. SCSI Backplane 2. SCSI Backplane Cable 3. System Board 1. DIMM Location J1 1. DIMM Location J2 1. DIMM Location J3 296 Netfinity Server HMM