IBM 86626RY Hardware Maintenance Manual - Page 58
Check the DIMM Error LEDs on the, lit DIMM Error LED.
![]() |
UPC - 087944501879
View all IBM 86626RY manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 58 highlights
- MEM LED on A memory error occurred. Actions: 1. Check the DIMM Error LEDs on the memory board. 2. Replace the DIMM indicated by the lit DIMM Error LED. 3. Replace the memory board. If the problem persists, go to "General checkout" on page 8. - FAN 1 LED on Fan 1 has failed or is operating too slowly. Note: A failing fan can also cause the TEMP and DASD1 LEDs to be on. Action: Replace fan 1. - FAN 2 LED on Fan 2 has failed or is operating too slowly. Note: A failing fan can also cause the TEMP and DASD1 LEDs to be on. Action: Replace fan 2. - FAN 3 LED on Fan 3 has failed or is operating too slowly. Note: A failing fan can also cause the TEMP and DASD1 LEDs to be on. Action: Replace fan 3. - FAN 4 LED on Fan 4 has failed or is operating too slowly. Note: A failing fan can also cause the TEMP and DASD1 LEDs to be on. Action: Replace fan 4. - TEMP LED on The system temperature has exceeded the maximum rating. Actions: 1. Check to see if a fan has failed. If it has, replace the fan. 2. Make sure the room temperature is not too hot. (See "Specifications" on page 61) If the problem persists, go to "General checkout" on page 8. - VRM LED on One of the voltage regulator modules on the processor board has failed. Actions: 50 Netfinity Server HMM