IBM 8863 Service Guide - Page 76
Warning
UPC - 000435474667
View all IBM 8863 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 76 highlights
000 The server passed the test. Do not replace a CRU or FRU. 195 The Esc key was pressed to end the test. Do not replace a CRU or FRU. 197 This is a warning error, but it does not indicate a hardware failure; do not replace a CRU or FRU. Take the action indicated in the "Action" column but do not replace a CRU or a FRU. See the description for Warning in the section "Diagnostic text messages" on page 59 for more information. v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, Type 8863," on page 93 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)", that step must be performed only by a trained service technician. Error code Description Action 001-198-000 Test aborted. 1. Check the system-error log and the BMC log for messages indicating the cause of the error, and take the indicated action. 2. From the diagnostic programs, run Quick Memory Test All Banks; then, if an error is detected, take the indicated action. Make sure you re-enable the memory in the Configuration/Setup Utility program. See, "Memory problems" on page 40. 3. Reinstall and, if necessary, update the BIOS code on the server; then, rerun the test (see "Updating the firmware" on page 133). 001-250-00x Test failed, where v x of 0 = ECC logic on I/O board v x of 1 = ECC logic on memory card 1. Check the system-error log and the BMC log for messages indicating the cause of the error, and take the indicated action. 2. From the diagnostic programs, run Quick Memory Test All Banks; then, if an error is detected, take the indicated action. 3. From the diagnostic programs, rerun the ECC test; then, if an error is detected, take the indicated action. 4. Reseat the following components: a. Memory card b. I/O board 5. Replace the components listed in step 4 one at a time, in the order shown, restarting the server each time. Make sure you re-enable the memory in the Configuration/Setup Utility program. See, "Memory problems" on page 40 001-292-000 Core system: failed/CMOS checksum failed. Load the BIOS default settings using the Configuration/Setup Utility program and run the test again (see "Configuration/Setup Utility menu choices" on page 135). 001-xxx-000 Failed core tests. 1. Reseat the I/O board. 2. Replace the I/O board. 001-xxx-001 Failed core tests. 1. Reseat the I/O board. 2. Replace the I/O board. 60 IBM xSeries 366 Type 8863: Problem Determination and Service Guide