IBM 8863 Service Guide - Page 89

programming

Page 89 highlights

v Follow the suggested actions in the order in which they are listed in the Action column until the problem is solved. v See Chapter 3, "Parts listing, Type 8863," on page 93 to determine which components are customer replaceable units (CRU) and which components are field replaceable units (FRU). v If an action step is preceded by "(Trained service technician only)", that step must be performed only by a trained service technician. Error code Description Action 180-xxx-006 Failed memory card LED test. 1. Reseat the following components: a. Memory card b. Microprocessor tray c. I/O board 2. Replace the following components one at a time, in the order shown, restarting the server each time. a. Memory card b. (Trained service technician only) Microprocessor tray c. I/O board 180-xxx-007 Failed power supply fan LED test. 1. Reseat the following components: a. Power supply b. (Trained service technician only) Power supply structure c. I/O board 2. Replace the components listed in step 1 one at a time, in the order shown, restarting the server each time. 180-xxx-008 Failed I/O board LED test. 1. Reseat the I/O board. 2. Replace the I/O board. 180-xxx-009 Failed Active™ PCI LED test. 1. Reseat the following components: a. (Trained service technician only) PCI-X switch card assembly b. I/O board 2. Replace the components listed in step 1 one at a time, in the order shown, restarting the server each time. 201-198-000 Memory Test Aborted: Could not run the test; suspect microprocessor tray error. 1. Restart the server. 2. Run the diagnostic test again. 3. Reinstall the diagnostic programs (see "Updating the firmware" on page 133). 4. (Trained service technician only) Replace the microprocessor tray. 201-198-00n Memory Test Aborted: Could not run the test. Note: n = 1-9 (programming error). 1. Restart the server. 2. Run the diagnostic test again. 3. Reinstall the diagnostic programs (see "Updating the firmware" on page 133). Chapter 2. Diagnostics 73

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172

v
Follow
the
suggested
actions
in
the
order
in
which
they
are
listed
in
the
Action
column
until
the
problem
is
solved.
v
See
Chapter
3,
“Parts
listing,
Type
8863,”
on
page
93
to
determine
which
components
are
customer
replaceable
units
(CRU)
and
which
components
are
field
replaceable
units
(FRU).
v
If
an
action
step
is
preceded
by
“(Trained
service
technician
only)”,
that
step
must
be
performed
only
by
a
trained
service
technician.
Error
code
Description
Action
180-xxx-006
Failed
memory
card
LED
test.
1.
Reseat
the
following
components:
a.
Memory
card
b.
Microprocessor
tray
c.
I/O
board
2.
Replace
the
following
components
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
a.
Memory
card
b.
(Trained
service
technician
only)
Microprocessor
tray
c.
I/O
board
180-xxx-007
Failed
power
supply
fan
LED
test.
1.
Reseat
the
following
components:
a.
Power
supply
b.
(Trained
service
technician
only)
Power
supply
structure
c.
I/O
board
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
180-xxx-008
Failed
I/O
board
LED
test.
1.
Reseat
the
I/O
board.
2.
Replace
the
I/O
board.
180-xxx-009
Failed
Active
PCI
LED
test.
1.
Reseat
the
following
components:
a.
(Trained
service
technician
only)
PCI-X
switch
card
assembly
b.
I/O
board
2.
Replace
the
components
listed
in
step
1
one
at
a
time,
in
the
order
shown,
restarting
the
server
each
time.
201-198-000
Memory
Test
Aborted:
Could
not
run
the
test;
suspect
microprocessor
tray
error.
1.
Restart
the
server.
2.
Run
the
diagnostic
test
again.
3.
Reinstall
the
diagnostic
programs
(see
“Updating
the
firmware”
on
page
133).
4.
(Trained
service
technician
only)
Replace
the
microprocessor
tray.
201-198-00n
Memory
Test
Aborted:
Could
not
run
the
test.
Note:
n
=
1-9
(programming
error).
1.
Restart
the
server.
2.
Run
the
diagnostic
test
again.
3.
Reinstall
the
diagnostic
programs
(see
“Updating
the
firmware”
on
page
133).
Chapter
2.
Diagnostics
73