IBM HS20 Hardware Maintenance Manual - Page 80

System Management: Failed

Page 80 highlights

Note: See "System" on page 94 to determine which components should be replaced by a field service technician. Error code/symptom FRU/action 166-201-003 System Management: Failed 1. I/O adapter (I2C bus error(s) See SERVPROC and DIAGS entries in event log.) 2. System board 166-201-004 System Management: Failed 1. SCSI storage expansion unit (I2C bus error(s) See SERVPROC and DIAGS entries in event log.) 2. System board 166-201-005 System Management: Failed 1. DIMMs (I2C bus error(s) See SERVPROC and DIAGS entries in event log.) 2. Microprocessors 3. System board 166-342-000 System Management: Failed 1. Ensure the latest firmware levels for Remote Supervisor (ASM adapter BIST indicate failed tests.) Adapter and BIOS are installed. 2. Power down blade server and reseat it in chassis. 3. Remote Supervisor Adapter. 166-400-000 System Management: Failed 1. Reflash or update firmware for ISMP. (ISMP self test result failed tests: x where x = Flash, RAM, or ROM.) 2. System board. 180-XXX-000 (Diagnostics LED failure) v Run diagnostics panel LED test for the failing LED. 180-XXX-001 (Failed front LED panel test) 1. Front bezel with customer interface card 2. System board 180-XXX-002 (Failed diagnostics LED panel test) v System board 180-XXX-003 (Failed system board LED test) v System board 180-XXX-005 (Failed SCSI backplane LED test) 1. SCSI storage expansion unit 2. System board 201-XXX-0nn (Failed memory test.) 1. DIMM Location slots 1-4 where nn = DIMM location. Note: nn 1=DIMM 1; 2=DIMM 2; 3=DIMM 3; 4=DIMM 4. 2. System board. 202-XXX-001 (Failed system cache test) 1. Microprocessor 1 2. System board 202-XXX-002 (Failed system cache test) 1. Microprocessor 2 2. System board 217-198-XXX (Could not establish drive parameters) v SCSI storage expansion unit 217-XXX-000 (Failed hard disk drive test) Note: If RAID is configured, the hard disk drive number refers to the RAID logical array. v Hard disk drive 1 217-XXX-001 (Failed hard disk test) Note: If RAID is configured, the hard disk number refers to the RAID logical array. v Hard disk drive 2 70 BladeCenter HS20 Type 8832: Hardware Maintenance Manual and Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158

Note:
See “System” on page 94 to determine which components should be replaced by a field service technician.
Error code/symptom
FRU/action
166-201-003 System Management: Failed
(I2C bus error(s) See SERVPROC and
DIAGS entries in event log.)
1.
I/O adapter
2.
System board
166-201-004 System Management: Failed
(I2C bus error(s) See SERVPROC and
DIAGS entries in event log.)
1.
SCSI storage expansion unit
2.
System board
166-201-005 System Management: Failed
(I2C bus error(s) See SERVPROC and
DIAGS entries in event log.)
1.
DIMMs
2.
Microprocessors
3.
System board
166-342-000 System Management: Failed
(ASM adapter BIST indicate failed tests.)
1.
Ensure the latest firmware levels for Remote Supervisor
Adapter and BIOS are installed.
2.
Power down blade server and reseat it in chassis.
3.
Remote Supervisor Adapter.
166-400-000 System Management: Failed
(ISMP self test result failed tests:
x
where
x
= Flash, RAM, or ROM.)
1.
Reflash or update firmware for ISMP.
2.
System board.
180-XXX-000
(Diagnostics LED failure)
v
Run diagnostics panel LED test for the failing LED.
180-XXX-001
(Failed front LED panel test)
1.
Front bezel with customer interface card
2.
System board
180-XXX-002
(Failed diagnostics LED panel test)
v
System board
180-XXX-003
(Failed system board LED test)
v
System board
180-XXX-005
(Failed SCSI backplane LED test)
1.
SCSI storage expansion unit
2.
System board
201-XXX-0nn
(Failed memory test.)
1.
DIMM Location slots 1-4 where
nn
= DIMM location.
Note:
nn
1=DIMM 1; 2=DIMM 2; 3=DIMM 3; 4=DIMM 4.
2.
System board.
202-XXX-001
(Failed system cache test)
1.
Microprocessor 1
2.
System board
202-XXX-002
(Failed system cache test)
1.
Microprocessor 2
2.
System board
217-198-XXX
(Could not establish drive parameters)
v
SCSI storage expansion unit
217-XXX-000
(Failed hard disk drive test)
Note:
If RAID is configured, the hard disk
drive number refers to the RAID logical
array.
v
Hard disk drive 1
217-XXX-001
(Failed hard disk test)
Note:
If RAID is configured, the hard disk
number refers to the RAID logical array.
v
Hard disk drive 2
70
BladeCenter HS20 Type 8832: Hardware Maintenance Manual and Troubleshooting Guide