IBM HS40 Hardware Maintenance Manual - Page 111

Temperature-related, system, shutdown, drive, checkout, Undetermined, problems

Page 111 highlights

Temperature-related system shutdown Note: See Chapter 7, "Parts listing, Type 8839," on page 105 to determine which components should be replaced by a field service technician. Message Action System shutoff due to CPU x over temperature 1. Ensure that the system is being properly cooled; see "System reliability considerations" on page 33. 2. Replace microprocessor x. System shutoff due to Blade Storage Expansion option temperature 1. Ensure that the system is being properly cooled; see "System reliability considerations" on page 33. 2. Replace Blade Storage Expansion option. CPU x shut off due to over temperature 1. Ensure that the system is being properly cooled; see "System reliability considerations" on page 33. 2. Replace microprocessor x. Critical Blower Failure, blade server powering down See IBM BladeCenter Type 8677 Hardware Maintenance Manual and Troubleshooting Guide. Power Modules are over temperature, blade server powering down See IBM BladeCenter Type 8677 Hardware Maintenance Manual and Troubleshooting Guide. Hard disk drive checkout Note: See Chapter 7, "Parts listing, Type 8839," on page 105 to determine which components should be replaced by a field service technician. Message Action Hard drive x removal detected (level-critical; hard drive x has been removed) Information only, take action as appropriate. Undetermined problems Note: When troubleshooting a problem in the blade server, you must determine whether the problem is a blade server problem or a problem with the BladeCenter unit. v If the BladeCenter unit contains more than one blade server and only one of the blade servers exhibits the problem, it is likely that it is a blade server problem. v If all of the blade servers exhibit the same symptom, it is probably a BladeCenter unit problem; for more information, see the IBM BladeCenter Type 8677 Hardware Maintenance Manual and Troubleshooting Guide. Use the information in this section if the diagnostic tests did not diagnose the failure, the devices list is incorrect, or the system is inoperative. Chapter 6. Symptom-to-FRU index 101

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172

Temperature-related
system
shutdown
Note:
See
Chapter
7,
“Parts
listing,
Type
8839,”
on
page
105
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Message
Action
System
shutoff
due
to
CPU
x
over
temperature
1.
Ensure
that
the
system
is
being
properly
cooled
;
see
“System
reliability
considerations”
on
page
33.
2.
Replace
microprocessor
x
.
System
shutoff
due
to
Blade
Storage
Expansion
option
temperature
1.
Ensure
that
the
system
is
being
properly
cooled
;
see
“System
reliability
considerations”
on
page
33.
2.
Replace
Blade
Storage
Expansion
option.
CPU
x
shut
off
due
to
over
temperature
1.
Ensure
that
the
system
is
being
properly
cooled
;
see
“System
reliability
considerations”
on
page
33.
2.
Replace
microprocessor
x
.
Critical
Blower
Failure,
blade
server
powering
down
See
IBM
BladeCenter
Type
8677
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
.
Power
Modules
are
over
temperature,
blade
server
powering
down
See
IBM
BladeCenter
Type
8677
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
.
Hard
disk
drive
checkout
Note:
See
Chapter
7,
“Parts
listing,
Type
8839,”
on
page
105
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Message
Action
Hard
drive
x
removal
detected
(level-critical;
hard
drive
x
has
been
removed)
Information
only,
take
action
as
appropriate.
Undetermined
problems
Note:
When
troubleshooting
a
problem
in
the
blade
server,
you
must
determine
whether
the
problem
is
a
blade
server
problem
or
a
problem
with
the
BladeCenter
unit.
v
If
the
BladeCenter
unit
contains
more
than
one
blade
server
and
only
one
of
the
blade
servers
exhibits
the
problem,
it
is
likely
that
it
is
a
blade
server
problem.
v
If
all
of
the
blade
servers
exhibit
the
same
symptom,
it
is
probably
a
BladeCenter
unit
problem;
for
more
information,
see
the
IBM
BladeCenter
Type
8677
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
.
Use
the
information
in
this
section
if
the
diagnostic
tests
did
not
diagnose
the
failure,
the
devices
list
is
incorrect,
or
the
system
is
inoperative.
Chapter
6.
Symptom-to-FRU
index
101