IBM HS40 Hardware Maintenance Manual - Page 92

following, errors, appear, screen, during, management-module, error

Page 92 highlights

Note: See Chapter 7, "Parts listing, Type 8839," on page 105 to determine which components should be replaced by a field service technician. Error code/symptom FRU/action 84F2 (Server management interface failed) 1. Update the BMC and SDRs with the most current versions that are compatible with your system configuration. 2. I/O board. 84F3 (BMC in update mode) 1. The BMC recovery jumper is in the active position and the BMC can be updated. 2. After updating the BMC, move the jumper to the inactive position. 84F4 (Sensor Data Record empty) 1. Update the BMC and SDRs with the most current versions that are compatible with your system configuration. 2. I/O board. 3. Processor board. 84FF (System Event Log full) Clear the System Event Log. 00150900 (SERR/PERR detected on PCI bus.) 1. PCI-X adapter 2. I/O board 00151730 (IMB parity/CRC error) 1. DIMM 2. Processor board The following errors appear on the screen during POST and in the management-module error log. Note: See Chapter 7, "Parts listing, Type 8839," on page 105 to determine which components should be replaced by a field service technician. Error code/symptom FRU/action Microprocessor 1 internal error (IERR) 1. Run the Configuration/Setup Utility program, and enable the microprocessor retest. 2. Microprocessor 1. 3. Processor board. Microprocessor 2 internal error (IERR) 1. Run the Configuration/Setup Utility program, and enable the microprocessor retest. 2. Microprocessor 2. 3. Processor board. Microprocessor 3 internal error (IERR) 1. Run the Configuration/Setup Utility program, and enable the microprocessor retest. 2. Microprocessor 3. 3. Processor board. Microprocessor 4 internal error (IERR) 1. Run the Configuration/Setup Utility program, and enable the microprocessor retest. 2. Microprocessor 4. 3. Processor board. 82 BladeCenter HS40 Type 8839: Hardware Maintenance Manual and Troubleshooting Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171
  • 172

Note:
See
Chapter
7,
“Parts
listing,
Type
8839,”
on
page
105
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Error
code/symptom
FRU/action
84F2
(Server
management
interface
failed)
1.
Update
the
BMC
and
SDRs
with
the
most
current
versions
that
are
compatible
with
your
system
configuration.
2.
I/O
board.
84F3
(BMC
in
update
mode)
1.
The
BMC
recovery
jumper
is
in
the
active
position
and
the
BMC
can
be
updated.
2.
After
updating
the
BMC,
move
the
jumper
to
the
inactive
position.
84F4
(Sensor
Data
Record
empty)
1.
Update
the
BMC
and
SDRs
with
the
most
current
versions
that
are
compatible
with
your
system
configuration.
2.
I/O
board.
3.
Processor
board.
84FF
(System
Event
Log
full)
Clear
the
System
Event
Log.
00150900
(SERR/PERR
detected
on
PCI
bus.)
1.
PCI-X
adapter
2.
I/O
board
00151730
(IMB
parity/CRC
error)
1.
DIMM
2.
Processor
board
The
following
errors
appear
on
the
screen
during
POST
and
in
the
management-module
error
log.
Note:
See
Chapter
7,
“Parts
listing,
Type
8839,”
on
page
105
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Error
code/symptom
FRU/action
Microprocessor
1
internal
error
(IERR)
1.
Run
the
Configuration/Setup
Utility
program,
and
enable
the
microprocessor
retest.
2.
Microprocessor
1.
3.
Processor
board.
Microprocessor
2
internal
error
(IERR)
1.
Run
the
Configuration/Setup
Utility
program,
and
enable
the
microprocessor
retest.
2.
Microprocessor
2.
3.
Processor
board.
Microprocessor
3
internal
error
(IERR)
1.
Run
the
Configuration/Setup
Utility
program,
and
enable
the
microprocessor
retest.
2.
Microprocessor
3.
3.
Processor
board.
Microprocessor
4
internal
error
(IERR)
1.
Run
the
Configuration/Setup
Utility
program,
and
enable
the
microprocessor
retest.
2.
Microprocessor
4.
3.
Processor
board.
82
BladeCenter
HS40
Type
8839:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide