Position Bead on the Groove Step, 21. Detailed Thermocouple Bead Placement, 22. Third
UPC - 683728169121
View all Intel E2180 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 98 highlights
Case Temperature Reference Metrology Figure 7-20. Position Bead on the Groove Step Kapton* tape Wire section into the groove to prepare for final bead placement Figure 7-21. Detailed Thermocouple Bead Placement TC Wire with Insulation IHS with Groove Figure 7-22. Third Tape Installation TC Bead 98 Thermal and Mechanical Design Guidelines
Case Temperature Reference Metrology
98
Thermal and Mechanical Design Guidelines
Figure
7-20. Position Bead on the Groove Step
Figure
7-21. Detailed Thermocouple Bead Placement
TC Wire with Insulation
IHS with Groove
TC Bead
Figure
7-22. Third Tape Installation
Wire section
into the
groove to
prepare for
final bead
placement
Kapton*