Intel S1200RP Service Guide - Page 122

Server Management Screen, Assert NMI on SERR

Page 122 highlights

Server Utilities Main Advanced Security Assert NMI on SERR Assert NMI on PERR Reset on CATERR Resume on AC Power Loss Power Restore Delay Power Restore Delay Value Clear System Event Log FRB-2 Enable OS Boot Watchdog Timer OS Boot Watchdog Timer Policy OS Boot Watchdog Timer Timeout Plug & Play BMC Detection EuP LOT6 Off-Mode ► Console Redirection ► System Information ► BMC LAN Configuration Server Management Boot Options Boot Manager Enabled / Disabled Enabled / Disabled Enabled / Disabled Stay Off / Last State / Power On Disabled / Auto / Fixed [25 - 300s, 25 is default] Enabled / Disabled Enabled / Disabled Enabled / Disabled Power off / Reset 5 minutes / 10 minutes / 15 minutes / 20 minutes Enabled / Disabled Enabled / Disabled Figure 93. Server Management Screen Screen Field Descriptions: 1. Assert NMI on SERR Option Values: Enabled Disabled Help Text: On SERR, generate an NMI and log an error. Note: [Enabled] must be selected for the Assert NMI on PERR setup option to be visible. Comments: This option allows the system to generate an NMI when an SERR occurs, which is a method Legacy Operating System error handlers may use instead of processing a Machine Check. 110 Intel® Server System R1000RP Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171

Server Utilities
110
Intel
®
Server System R1000RP Service Guide
Main
Advanced
Security
Server Management
Boot Options
Boot Manager
Assert NMI on SERR
Enabled
/ Disabled
Assert NMI on PERR
Enabled
/ Disabled
Reset on CATERR
Enabled
/ Disabled
Resume on AC Power Loss
Stay Off
/ Last State / Power On
Power Restore Delay
Disabled
/ Auto / Fixed
Power Restore Delay Value
[25
300s,
25
is default]
Clear System Event Log
Enabled /
Disabled
FRB-2 Enable
Enabled
/ Disabled
OS Boot Watchdog Timer
Enabled /
Disabled
OS Boot Watchdog Timer Policy
Power off
/ Reset
OS Boot Watchdog Timer Timeout
5 minutes /
10 minutes
/ 15 minutes / 20 minutes
Plug & Play BMC Detection
Enabled /
Disabled
EuP LOT6 Off-Mode
Enabled /
Disabled
Console Redirection
System Information
BMC LAN Configuration
Figure 93. Server Management Screen
Screen Field Descriptions:
1.
Assert NMI on SERR
Option Values:
Enabled
Disabled
Help Text:
On SERR, generate an NMI and log an error.
Note:
[Enabled] must be selected for the Assert NMI on PERR setup option to be visible.
Comments:
This option allows the system to generate an NMI when an SERR occurs,
which is a method Legacy Operating System error handlers may use instead of processing a
Machine Check.