Intel S1200RP Service Guide - Page 58

Installing and Removing a Slimline Optical Drive

Page 58 highlights

Hardware Installations and Upgrades Installing and Removing a Slimline Optical Drive Caution: The slimline optical drive is NOT hot-swappable. Before removing or replacing the drive, you must first: 1. Take the server out of service. 2. Turn off all peripheral devices connected to the system. 3. Turn off the system by pressing the power button. 4. Unplug the power cord from the system or wall outlet. Note: To maintain proper system cooling, a filler panel must be installed if you do not install a device at this location. Installing a Slimline Optical Drive 1. Install the plastic guide onto the back of the drive and attach with two screws as shown (see letter A). Figure 54. Installing the Plastic Guide to the Optical Drive 2. Insert the optical drive into chassis opening and push all the way until it stops (see letter B). 3. Connect the cables as shown (see letter C). Figure 55. Installing an Optical Drive 46 Intel® Server System R1000RP Service Guide

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129
  • 130
  • 131
  • 132
  • 133
  • 134
  • 135
  • 136
  • 137
  • 138
  • 139
  • 140
  • 141
  • 142
  • 143
  • 144
  • 145
  • 146
  • 147
  • 148
  • 149
  • 150
  • 151
  • 152
  • 153
  • 154
  • 155
  • 156
  • 157
  • 158
  • 159
  • 160
  • 161
  • 162
  • 163
  • 164
  • 165
  • 166
  • 167
  • 168
  • 169
  • 170
  • 171

Hardware Installations and Upgrades
46
Intel
®
Server System R1000RP Service Guide
Installing and Removing a Slimline Optical Drive
Caution:
The slimline optical drive is NOT hot-swappable. Before removing or replacing the drive,
you must first:
1.
Take the server out of service.
2.
Turn off all peripheral devices connected to the system.
3.
Turn off the system by pressing the power button.
4.
Unplug the power cord from the system or wall outlet.
Note:
To maintain proper system cooling, a filler panel must be installed if you do not install a
device at this location.
Installing a Slimline Optical Drive
1.
Install the plastic guide onto the back of the drive and attach with two screws as shown (see
letter
A
).
Figure 54. Installing the Plastic Guide to the Optical Drive
2.
Insert the optical drive into chassis opening and push all the way until it stops (see letter
B
).
3.
Connect the cables as shown (see letter
C
).
Figure 55. Installing an Optical Drive