JVC GY-DV700WUCL Instruction Manual - Page 35
POWER SUPPLY, 4-1 AC Operation, 4-2 Battery Pack Operation
View all JVC GY-DV700WUCL manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 35 highlights
4. POWER SUPPLY The GY-DV700W is operable with AC power supply or battery pack. 4-1 AC Operation Use the JVC AA-P250 AC power adapter (max. rated output 12.5 V DC, 3.5 A) as the AC power supply. AC power adapter DC cable EARPHONE DV CH-1 AUDIO IN CH-2 LINE MIC LINE MIC DC INPUT +48V ON +48V ON TALLY DC OUTPUT Precautions for Connection with the AC POWER ADAPTER(AA-P250) Always use the DC cable equipped with a ferrite core and supplied with the AA-P250. The DC cable VC-710(5m) can not be used. If the cable is not equipped with a ferrite core, please contact your JVC dealer. Do not use any power source with large fluctuations in the power source voltage, or power sources generating noise, such as ripples. 1. After making sure that the power switches of the GY- DV700W and of the AA-P250 are set to OFF, connect the DC cable from the AA-P250 to the DC INPUT connector of the GY-DV700W as shown in the illustration. 2. When the AA-P250 is used, set the CHARGE/CAMERA switch to CAMERA. 3. Press the POWER switch of the GY-DV700W to ON. Power is supplied to the VCR section and the camera. * For details, read the instruction manual of the AA-P250. Note: Do not remove or connect the DC cable while recording is being performed. 4-2 Battery Pack Operation The GY-DV700W can be operated with the following battery packs. Ⅲ Flat shape type battery pack Ⅲ Anton-Bauer battery pack ● Propack 13/14 Series ● Trimpack 13/14 Series ● Magnum 13/14 Series ● Compack 13/14 Series * An Anton-Bauer battery pack cannot be connected directly to the GY-DV700W. It is necessary to mount the optional battery holder. Battery holder: Anton-Bauer QRQ27 For details on how to mount the battery holder, see page 37. ● When the DC cable is connected to the DC INPUT connector, the power supply from the battery pack is interrupted and the power starts to be supplied through the DC INPUT connector. ● Do not connect or disconnect the DC cable while operating with a battery pack. The following symptoms may occur if the DC cable is connected or disconnected while operating with a battery pack. • The power is cut off for a moment when the DC cable is disconnected. • Noise to the video and audio signals occurs. Audio signal are muted. ● When operation is continued with DC input after the battery pack capacity has been used up, set the POWER switch to OFF after the DC power is applied. Then switch ON again. ● If the GY-DV700W is left with the battery pack attached, a small amount of power is consumed even if the POWER switch on the GY-DV700W is set to OFF. Remove the battery pack when the GY-DV700W is not going to be used. 35