JVC GY-DV700WUCL Instruction Manual - Page 58

Recording Time Codes by Slave-Locking the Built-in Time Code Generator with the External TCG

Page 58 highlights

9. TIME CODE OPERATION 9-3 Recording Time Codes by Slave-Locking the Built-in Time Code Generator with the External TCG The built-in time code generator can be synchronized (slave-locked) with the SMPTE-standard LTC time code signal which is input through the TC IN connector. Once the slave locking has been carried out, the built-in time code generator runs even when the external time code input stops. Even when the power is switched off, it continues to run on the backup lithium battery. Sync signal generator PUSH External time code generator REF Video signal DV CAMCORDER GY-DV700W REF Video signal LTC time code signal Y/C OUT MONITOR OUT LINE OUT CH-1 CH-2 TC IN TC OUT VTR REMOTE TC IN connector SYNC IN TEST OUT MIC IN LENS SYNC IN connector 1. Input the reference video signal into the external time code generator and the SYNC IN connector of this unit. Note : When the power is switched ON while external sync signal is input, the screen moves in a vertical direction for a few seconds. This is not a malfunction. 2. Input the SMPTE standard LTC time code signal into the TC IN connector. 3. Display time code on the counter display. 4. Set the switches in the TC GENERATOR block as follows. • Set the PRESET/REGEN switch to "PRESET". • Set the REC/FREE switch to "FREE". * While the REC/FREE switch is set to "REC", slave- locking will not take place. Ⅵ Set the related VCR Setup Menus. • Set the VCR Setup Menu item No. 398 SSF MODE to "OFF". * If set to CUE mode or MARK mode, the slave-locking will not take place. • Set the VCR Setup Menu item No. 403 U-BIT SLAVE. Set to "TC&UB" when the user's bits should also be slavelocked with the external time code generator. • The framing mode will be automatically the same mode as the entered time code (drop frame of non-drop frame). During the non-drop frame mode, the NDF indicator will light on the display. During the drop frame mode, the DF indicator will light on the display. 5. Set and operate the external time code generator. ➡ The built-in time code generator is slave-locked with the input external time code data. The SLAVE indicator lights on the display. SLAVE H M S F * If the external time code generator phase is not genlocked with the phase of the camera video signals, the "SLAVE" display will flicker. • Once slave locking has been made, the built-in time code generator keeps on running even when the external time code generator is stopped. Note : Do not connect or disconnect slaves during recording as this may disturb the servo lock. Multi-Camcorder Master-Slave Connection When there is only one slave GY-DV700W, connect it as indicated in the figure below. When connecting several GY-DV700Ws as slaves, input the REF video signal to SYNC IN connectors of all these units from the sync signal generator. MASTER SLAVE PUSH PUSH DV CAMCORDER GY-DV700W DV CAMCORDER GY-DV700W 58 Y/C OUT MONITOR OUT LINE OUT CH-1 CH-2 TC IN TC OUT VTR REMOTE SYNC IN TEST OUT MIC IN LENS TC OUT MONITOR OUT Y/C OUT MONITOR OUT LINE OUT CH-1 CH-2 TC IN TC OUT VTR REMOTE SYNC IN TEST OUT MIC IN LENS TC IN SYNC IN

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95

58
9. TIME CODE OPERATION
9-3
Recording Time Codes by Slave-Locking the Built-in Time Code Generator with the External TCG
The built-in time code generator can be synchronized (slave-locked) with the SMPTE-standard LTC time code signal which is input
through the TC IN connector. Once the slave locking has been carried out, the built-in time code generator runs even when the
external time code input stops. Even when the power is switched off, it continues to run on the backup lithium battery.
1.
Input the reference video signal into the external time code
generator and the SYNC IN connector of this unit.
2.
Input the SMPTE standard LTC time code signal into the
TC IN connector.
3.
Display time code on the counter display.
4.
Set the switches in the TC GENERATOR block as follows.
Set the PRESET/REGEN switch to “PRESET”.
Set the REC/FREE switch to “FREE”.
*
While the REC/FREE switch is set to “REC”, slave-
locking will not take place.
²
Set the related VCR Setup Menus.
Set the VCR Setup Menu item No. 398 SSF MODE to
“OFF”.
*
If set to CUE mode or MARK mode, the slave-locking
will not take place.
Set the VCR Setup Menu item No. 403 U-BIT SLAVE.
Set to “TC&UB” when the user’s bits should also be slave-
locked with the external time code generator.
The framing mode will be automatically the same mode
as the entered time code (drop frame of non-drop frame).
During the non-drop frame mode, the NDF indicator will
light on the display.
During the drop frame mode, the DF indicator will light
on the display.
5.
Set and operate the external time code generator.
The built-in time code generator is slave-locked with the
input external time code data.
The SLAVE indicator lights on the display.
*
If the external time code generator phase is not genlocked
with the phase of
the camera video signals, the “SLAVE”
display will flicker.
Once slave locking has been made, the built-in time code
generator keeps on running even when the external time
code generator is stopped.
Note :
Do not connect or disconnect slaves during recording as
this may disturb the servo lock.
Note :
When the power is switched ON while external sync
signal is input, the screen moves in a vertical direction
for a few seconds. This is not a malfunction.
Multi-Camcorder Master-Slave Connection
When there is only one slave GY-DV700W, connect it as
indicated in the figure below.
When connecting several GY-DV700Ws as slaves, input the
REF video signal to SYNC IN connectors of all these units from
the sync signal generator.
TC
OUT
TC
IN
VTR
REMOTE
SYNC IN
MIC IN
LENS
TEST OUT
Y/C OUT MONITOR OUT
LINE OUT
CH-1
CH-2
PUSH
DV CAMCORDER
GY-DV700W
Sync signal generator
External time code generator
REF Video signal
REF Video signal
LTC time code signal
TC IN
connector
SYNC IN
connector
H
SLAVE
M
S
F
TC
OUT
TC
IN
VTR
REMOTE
SYNC IN
MIC IN
LENS
TEST OUT
Y/C OUT MONITOR OUT
LINE OUT
CH-1
CH-2
PUSH
DV CAMCORDER
GY-DV700
W
TC
OUT
TC
IN
VTR
REMOTE
SYNC IN
MIC IN
LENS
TEST OUT
Y/C OUT MONITOR OUT
LINE OUT
CH-1
CH-2
PUSH
DV CAMCORDER
GY-DV700
W
MASTER
SLAVE
MONITOR OUT
TC OUT
TC IN
SYNC IN