Konica Minolta C3080P AccurioPress C2070/C3080 Series Daily Maintenance Guide
Konica Minolta C3080P Manual
View all Konica Minolta C3080P manuals
Add to My Manuals
Save this manual to your list of manuals |
Konica Minolta C3080P manual content summary:
- Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 1
- Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 2
in this manual 7 CAUTION - This symbol indicates that negligence of the instructions may User's Guide. This guide describes product names and system configurations as follows. Product name Conventions used in this guide AccurioPress C2070/C2070P/ C2060, AccurioPrint C2060L, AccurioPress C3080 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 3
of this machine: - Operator: Person who has been trained by Konica Minolta or authorized partner to operate the system for its intended use as well as manage consumables, and perform the maintenance and troubleshooting described in user's guides. Everyone who uses this system must have read and - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 4
Order...2-6 How to Operate the Both Sides Adj. Item 2-7 Finely adjust the side guide plates of the paper tray (for PF-707/PF-707m/PF-602m 2-7 [Front screen 3-6 Adjustment timing ...3-6 Adjustment sequence ...3-6 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-1 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 5
Adj.]...3-67 Checking the Color Density Control Setting 3-70 [Color Density Manual Control] ...3-73 About Controller Calibration ...3-76 Executing Calibration...3-77 About 3-101 [Package Color Auto Adj.]...3-103 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-2 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 6
1 Daily Care - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 7
page 1-9 page 1-13 page 1-15 Care requirements - Alcohol for cleaning - Soft cloth - Non-woven cloth with no pilling Tips - If you have a toner-dedicated vacuum cleaner, you can use it to clean the duplex part. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-2 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 8
paper feed route. 1 Open the front door. 2 Turn ON the main power switch, and turn ON the sub power switch. 3 Lower the lever [M1] counterclockwise. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-3 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 9
. Be sure to clean in the axis direction. Cleaning in the paper feed direction causes toner from dropping in the paper feed route. When cleaning, exercise care not to deform the roller and the pre-fusing part. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-4 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 10
cover [M3]. 11 Push the duplex part into the main body, then return the lever [M1] to its original position. 12 Close the front door. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-5 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 11
ON the main power switch, and turn ON the sub power switch. 3 Pull out Tray 1. 4 Close the left side door. 5 Open the paper feed roller. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-6 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 12
paper is seated properly, close the paper feed roller. 8 If the inside of Tray 1 is dirty, wipe off toner stains using a soft cloth. 9 Return Tray 1 to its original position. 10 Also, clean Tray 2 in the same way. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-7 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 13
dirty, wipe off stains using a soft cloth dampened with alcohol (cleaner). When the pick-up roller rotates after one sheet was fed, perform cleaning again. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-8 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 14
roller using a soft cloth dampened with alcohol (cleaner). 6 Return the upper tray to its original position. 7 Also, clean the lower tray in the same way. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-9 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 15
1.5 Cleaning Paper Feed Unit PF-602m 1 8 Open the tray left side door. 9 Open the lever [PF1]. 10 Wipe off stains on the inside using a clean soft cloth. 11 Close the lever [PF1]. 12 Open the lever [PF2]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-10 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 16
[PF3]. 15 Wipe off stains on the inside using a clean soft cloth. 16 Close the lever [PF3] and lever [PF2]. 17 Open the lever [PF5]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-11 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 17
1.5 Cleaning Paper Feed Unit PF-602m 1 18 Wipe off stains on the inside using a clean soft cloth. 19 Close the lever [PF5]. 20 Close the tray left side door. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-12 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 18
left side door. 2 Open the lever [PF1]. 3 Wipe off stains on the inside using a clean soft cloth. 4 Close the lever [PF1]. 5 Open the lever [PF2]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-13 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 19
the lever [PF4]. 9 Wipe off stains on the inside using a clean soft cloth. 10 Close the lever [PF4]. 11 Close the tray left side door. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-14 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 20
LU-202m, Large Capacity Unit LU202XL, or Large Capacity Unit LU-202XLm are dirty, wipe off stains using a soft cloth dampened with cleansing alcohol (cleaner). AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-15 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 21
1.7 Cleaning Large Capacity Unit LU-202m, Large Capacity Unit LU-202XL, or Large Capacity Unit LU- 202XLm 1 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 1-16 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 22
2 Both Sides Adjust - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 23
is output • Just before a job with a wide printing area is output • When both-side accuracy is not desirable (you want to increase both-side accuracy) AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-2 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 24
Adjustment order 1 2 3 Adjustment item Finely adjust the side guide plates of the paper tray (for PF-707/PF707m/PF-602m) [AutoMeasure] Adjustment Registering Paper Profile Reference page 2-7 page 2-37 page 2-41 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-3 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 25
Glass) mounted Adjustment order 1 2 3 Adjustment item Finely adjust the side guide plates of the paper tray (for PF-707/PF707m/PF-602m) [Front] guide plates of the paper tray (for PF-707/PF707m/PF-602m) [AutoMeasure] Adjustment Reference page 2-7 page 2-37 AccurioPress C2070/C2070P/C2060/C3080 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 26
to page 2-48. Tips - When using [Periodical Both Sides Adjustment], manually make the image quality adjustment. The mark is printed on the chart to enable you to know from which paper tray the target job is printed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-5 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 27
-side accuracy is not desirable (you want to increase both-side accuracy) 2.4.2 Adjustment Order Adjustment order 1 Adjustment item Back Side Fine Adjustment Reference page 2-43 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-6 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 28
one and the handle of the rear one. If moved only with the front side guide plate, the side guide plates may not be fixed in position. 3 Load paper of the size to be adjusted. % Load about 100 sheets of paper. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-7 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 29
guide plates. % Pushing the lock release lever of the front side guide plate, move the side guide plates to align them to the paper. NOTICE Avoid making the gap between the side guide plates completely to the top. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-8 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 30
stack of paper to the left side of the tray. NOTICE Do not load above the limit level indicated on the side guide plate of the tray. Carefully load paper to be seated under the paper control lever at the air nozzle. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-9 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 31
and [COPY] screen. 2.5.2 [Front] Adjustment 1 Press [Paper Setting] on the [MACHINE] screen. 2 Press the tray in which the paper to be adjusted has been loaded. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-10 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 32
"Paper Size" or "Direction" different from that of the paper loaded in the tray, is grayed out, so you cannot select it. 5 Press [Change Set]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-11 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 33
Mode]. 9 When the [PRINT MODE] screen is displayed, press Start on the control panel. A test chart is printed. Print approximately three sheets for a test chart. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-12 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 34
below, also measure the lengths at points [1], [3], [5], and [7], then proceed to step 12. [2]: 200 mm ^ 0.3 mm [4]: 200 mm ^ 0.3 mm [6]: 200 mm ^ 0.3 mm [8]: 200 mm ^ 0.3 mm AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-13 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 35
the lengths at points [2], [4], [6], and [8] are included in the respective ranges shown below. [2]: 200 mm ^ 0.3 mm [4]: 200 mm ^ 0.3 mm [6]: 200 mm ^ 0.3 mm [8]: 200 mm ^ 0.3 mm AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-14 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 36
brand, weight, or size, press [Register & OK], then proceed to the next step. 2.5.3 [Gap] Adjustment (Back side adjustment) 1 Press [Paper Setting] on the [MACHINE] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-15 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 37
2.5 How to Operate the Both Sides Adj. Item 2 2 Press the tray you performed [Front] adjustment for. 3 Press [Change Set]. 4 Press [Both Sides Adj.]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-16 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 38
[PRINT MODE] screen is displayed, press Start on the control panel. A test chart is printed. Print approximately three sheets for a test chart. 7 Press [Exit PrintMode]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-17 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 39
sure to make note of the measurement values. 9 Press [a] to [d] of each point, and use the touch panel keypad or [,] / [+] to enter the measured value. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-18 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 40
print position using the second and third output charts. Repeat Step 10 to 13 until the front and back are aligned. 13 Press [Exit PrintMode]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-19 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 41
ratio and image position of the back side. To make adjustments including the front side, perform [AutoMeasure] adjustment, [Chart Adjustment], or [Zoom]/[Image Shift] adjustment. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-20 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 42
2.5 How to Operate the Both Sides Adj. Item 2 1 Press [Paper Setting] on the [MACHINE] screen. 2 Press the tray you performed [Front] adjustment for. 3 Press [Change Set]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-21 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 43
MODE] screen is displayed, press Start on the control panel. % Output the background sheet for measurement with the paper size of A3 or 11 e 17. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-22 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 44
press Start on the control panel. % You can output 20 or more of the adjustment charts but cannot scan more than 20 sheets for measurement. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-23 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 45
a distance of about 5 cm (2 inches) each from the vertical size guide and horizontal size guide, and align the left and top edges parallel to the vertical size guide and horizontal size guide on the original glass. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-24 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 46
sheet face down (facing to the original glass), and fit it to the vertical size guide and horizontal size guide as shown below. In doing so, be careful not to shift the position of the may not be performed properly. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-25 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 47
the dialog. % You may see the message [Scanning adjustment chart failed]. Follow the instruction on the screen to correctly set the adjustment chart and background sheet, and then press and discard the measure- AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-26 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 48
2.5 How to Operate the Both Sides Adj. Item 2 ment results obtained so far, press [Yes]. Restart the scan measurement from the first scanning procedure. To continue the scan measurement, press [No]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-27 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 49
: Set the back side of the adjustment chart face up (turned away from the original glass), with its top edge positioned to the back side. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-28 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 50
been used), the printing position of the front side has been poorly adjusted, or the adjustments of the reference positions are not completed. Confirm these AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-29 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 51
direction is not adjusted. 16 Press [OK]. 2.5.5 [Rotate/Skew] Adjustment Tips - If [User Setting] or [Administrator Setting] - [Common Setting] - [Both Sides Rotate/Skew] in [Both Sides Rotate/Skew] to [Enable]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-30 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 52
2.5 How to Operate the Both Sides Adj. Item 2 1 Press [Paper Setting] on the [MACHINE] screen. 2 Press the tray you performed [Front] adjustment for. 3 Press [Change Set]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-31 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 53
2.5 How to Operate the Both Sides Adj. Item 2 4 Press [Both Sides Adj.]. 5 Press [Rotate/Skew], and press [Chart Adjustment]. 6 Press [Print Mode]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-32 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 54
[PRINT MODE] screen is displayed, press Start on the control panel. % A test chart is printed. Print approximately three sheets for a test chart. 8 Press [Exit PrintMode]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-33 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 55
charts. A B % "A" (black guide) in the figure indicates the front side, and "B" (blue guide) indicates the back side (for explanation, guide B is shown in blue but printed in make note of the measurement values. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-34 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 56
is completed, press [Adjustment Start]. % The adjustment values you entered are applied to [Front] and [Back] on the [Rotate/Skew] screen. 12 Press [Chart Adjustment]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-35 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 57
of print position using the second and third output charts. % Repeat Step 9 to 14 until the front and back are aligned. 16 Press [Exit PrintMode]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-36 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 58
Sides Auto Adj.] to [ON]. You can then set [Periodical Adjustment] to [ON] or [OFF]. For the tray set to [ON], [Periodical Adjustment] is available. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-37 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 59
2.5 How to Operate the Both Sides Adj. Item 2 1 Press [Paper Setting] on the [MACHINE] screen. 2 Press the tray in which the paper to be adjusted has been loaded. 3 Press [Change Set]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-38 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 60
on the control panel. % Up to 20 adjustment charts can be printed out. As the number of charts increases, the accuracy of adjustment values rises. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-39 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 61
PrintMode]. 8 The [AutoMeasure] screen is displayed, and each adjustment value on this screen is updated. % Print out one adjustment chart, and check it. 9 Press [OK]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-40 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 62
, its contents will be newly registered as a paper profile. 1 Press [Paper Setting] on the [MACHINE] screen. 2 Select a tray, then press [Change Set]. 3 Press [Register & OK]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-41 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 63
paper brand for the paper profile name. 6 Check that the paper profile name you entered is displayed, then press [Close] to end the registration task. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-42 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 64
Sides Adj." is applied. 2 Press [Paper Setting] on the [MACHINE] screen. 3 Select the tray to which the job data is output, and press [Change Set]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-43 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 65
2.5 How to Operate the Both Sides Adj. Item 2 4 Press [Both Sides Adj.]. 5 Press [Back]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-44 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 66
front side is set to 400 mm and that of the image on the back side to 401 mm, enter [-0.25%] as the adjustment value. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-45 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 67
Press [Paper Setting] on the [MACHINE] screen. 11 Select the tray in which the paper to be adjusted has been loaded, then press [Change Set]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-46 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 68
[Up/Down] and [-0.3 mm] in [Right/Left]. The adjustment value is updated in 0.1mm steps. Adjustment range: [Up/Down] -10.0 to +10.0; [Right/Left] -3.0 to +3.0 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-47 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 69
is cleared, finish the adjustment. 2.5.9 [Periodical Both Sides Adj.] Configure settings for the periodical both-side adjustment. This menu item is Adjustment] and [Periodical Both Sides Adj.] in sequence. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-48 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 70
occurs. The defined value between 0.5 mm and 10.0 mm can be specified. (Default: 2.0 mm) 4 Press [OK]. The screen returns to the [Quality Adjustment Menu] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-49 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 71
2.5 How to Operate the Both Sides Adj. Item 2 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-50 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 72
3 Quality Adj. - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 73
changed dReference To not continuously perform the series of adjustment of the image quality adjustment flow, perform page 3-9, and then resume from the next adjustment. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-2 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 74
(Relay Unit RU-509/Relay Unit RU-518) is mounted Adjustment order 1 Adjustment item Color Density Control setting check 3 Reference page 3-76 Reference page 3-70 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-3 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 75
[Gamma Automatic Adjustment] [Max. Density Auto Adj.] [Maximum Density Adjustment] [Color density manual control] Reference page 3-70 page 3-9 page 3-67 page 3-49 page 3-73 Tips Type Color Adj.] is recommended. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-4 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 76
i1Pro2, or i1iSisXL) [Density Balance Adjustment] (for FD-5BT) [Color density manual control] Exact Color G7 Calibration Reference page 3-9 page 3-39 page 3-11 page calibration, contact your service representative. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-5 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 77
FD-5BT) [Color density manual control] Exact Color G7 service representative. - For "Color Density Control setting check", we recommend that you select [Each Paper Type Color Adj.] to use special paper or increase the accuracy of the automatic adjustment. AccurioPress C2070/C2070P/C2060/C3080 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 78
) This adjustment - (None) - (None) Next adjustment (Gamma Automatic Adjustment) 1 Press Utility/Counter on the machine's control panel. The [UTILITY] screen is displayed. 2 Press [Administrator Setting]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-7 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 79
3.6 Details of quality adjustment items 3 3 Press [System Setting]. 4 Press [Expert Adjustment]. 5 Press [Quality Adjustment]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-8 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 80
adjustment flow Adjustment flow when changing the screen Position of this adjustment Previous adjustment This adjustment Screen selection This adjustment Next adjustment Density Balance Adjustment AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-9 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 81
panel of the main body, press [Adjustment] on the [MACHINE] screen. The [Adjustment Menu] is displayed. 2 Press [Execute Adjust Operation] on the [Adjustment Menu] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-10 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 82
test charts. The application varies depending on your spectrophotometer. For i1-Pro, i1-Pro2, or i1iSisXL, use X-rite Measure Tool. Install the tool in advance. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-11 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 83
v5.0.10: https://xritephoto.com/ph_product_overview.aspx?ID=757&Action=Support&SoftwareID=931 0 To use the spectrophotometer, i1iSisXL, perform Step Adjustment] in sequence. 3 Press [Density Balance Chart Output]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-12 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 84
examples in English. To display menus and messages in English, select [Language] - [English] on the Measure Tool toolbar, and then restart the X-rite Measure tool. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-13 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 85
, click [Device/Port]. The [Instrument Configuration] screen is displayed. 9 In [Instrument], select the spectrophotometer to use. When [OK] is displayed, close the screen. Example: [Eye-One Pro] (i1Pro2) is selected. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 86
[Rows] and [Columns], and click [OK]. % When the spectrophotometer is "Type 1" of i1Pro2: [Columns] = 6, [Rows] = 5 % When the spectrophotometer is "Type 2" of i1Pro2: [Columns] = 6, [Rows] = 13 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-15 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 87
influence of the color of the table, place 10 sheets of paper of the same type as the chart underneath the chart to be measured. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-16 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 88
finished with the chart measurement, click [Close]. % Continuously, go to "Saving the measured data of the density balance" (page 3-19), and save the measurement data. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-17 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 89
according to the paper size, and click [Open]. There are some script data items particular for each chart size or type. For details, contact your service representative. 3 On the following screen, click [Start]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-18 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 90
density balance measured with the spectrophotometer to a USB device such as a USB memory stick or to the computer on the network used by the machine. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-19 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 91
network. Stored USB Memory Computer on the network Description Connect the USB memory to the computer. Create a folder named "\C2070\ADJUST_DATA" or "\C3080\ADJUST_DATA" in the root (immediately below) of the USB memory, and specify it as a storage destination. Open the computer connected to the - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 92
FD-S2w. Install the tool in advance. 0 For details on operations, refer to the user's guide supplied with FD-S2w. When FD-9 is used as the spectrophotometer, test charts with QR ensure efficient input work. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-21 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 93
be used. After the selection, press [Print Mode]. The recommended charts are as follows. - [Type 1] of [] - [Type 3] of [] AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-22 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 94
. 5 Set the paper on the [PRINT MODE] screen and press Start on the control panel. The color chart is output for measurement using the spectrophotometer. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-23 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 95
: Proceed to the next step to perform the white calibration. % No message appears: Proceed to step 11. 8 While [OK] is selected, press the OPTION button. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-24 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 96
from the plate. 11 On the computer where FD-S2w has been installed, select [Start] - [All Programs]- [KONICA MINOLTA] - [FD-S2w] - [FD-S2w] in sequence. 12 Click the [Density balance / Color density control] icon. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-25 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 97
chart list according to the type and paper size of the output chart. % Select [Type2] even when you output the Type3 chart. 15 Click [Measurement]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-26 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 98
side button. Slide FD-5BT to the bottom side, then release the side button. % For details about how to use FD-5BT, refer to the manual supplied with the spectrophotometer. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-27 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 99
measure. 19 After the measurement, the measurement data is created under the chart list that you used. Right click the measured data, and press [Save]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-28 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 100
3.6 Details of quality adjustment items 3 20 Enter the 14-digit identification number that is printed to the chart in [PrintID]. Example: 40213150117EBE 21 Enter a filename in [Additional File name]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-29 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 101
and click [Folder] and [Add]. Create a folder named "\C2070\ADJUST_DATA" or "\C3080\ADJUST_DATA" in the root (immediately below) of the USB memory, and specify it as to save, select the machine from [Printer]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-30 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 102
IP address of the machine % [Port]: 30091 25 Click [Save]. % When registering measurement data (density balance adjustment value) on the machine, proceed to page 3-32. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-31 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 103
the main body, press Utility/Counter. The [UTILITY] screen is displayed. 2 Press [Administrator Setting] - [System Setting] - [Expert Adjustment] - [Quality Adjustment] - [Density Balance Adjustment] in sequence. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-32 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 104
is overwritten. 5 The following screen is displayed. Connect the USB memory where the measured data has been saved to the main body, and press [OK]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-33 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 105
been saved, open a Web browser. % It is recommended that you log in to Web Utilities from the computer where the measured data has been saved. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-34 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 106
" at the end of the IP address is unnecessary. The main page of the Web Utilities is displayed. 3 Click on [Machine Manager Setting]. 4 Enter the [User Name] and [Password] and click [OK]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-35 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 107
[Upload]. % Enter the file name (Example: 2021115011C4CC_i1pro2_2012-10-15.txt). % Click [Browse] of the [File Path] and select the measured data saved in the computer. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-36 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 108
[UTILITY] screen is displayed. 8 Press [Administrator Setting] - [System Setting] - [Expert Adjustment] - [Quality Adjustment] - [Density Balance Adjustment] in sequence. 9 Press [Density Balance Data Reg/Del]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-37 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 109
data to be registered and press [OK]. 12 When the following screen is displayed, press [OK]. The adjusted value of the density balance is registered. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-38 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 110
adjustment has the following three types depending on the system configuration. Intelligent Quality Optimizer IQ-501 Mounted Not mounted Scanner ( Quality Adjustment] and [Density Balance Auto. Adj.] in sequence. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-39 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 111
3.6 Details of quality adjustment items 3 3 Press [Print Mode]. 4 Press [Quality Adj.]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-40 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 112
press [Screen Pattern] to display the [Screen Pattern] screen and select any screen. Select a screen, and press [OK]. % Press [Close] on the [Quality Adjustment] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-41 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 113
balance chart from the machine to carry out colorimetry using the scanner function. 1 Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-42 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 114
3.6 Details of quality adjustment items 3 2 Press [Quality Adjustment] and [Density Balance Auto. Adj.] in sequence. 3 Press [Output Chart]. 4 Press [Quality Adj.]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-43 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 115
press [Screen Pattern] to display the [Screen Pattern] screen and select any screen. Select a screen, and press [OK]. % Press [Close] on the [Quality Adjustment] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-44 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 116
chart away from the vertical size guide by 2 inches (5 cm), then push it against the horizontal size guide to load the test chart. % Place about 10 sheets of blank copy paper on the test chart. % Close the ADF. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-45 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 117
first scan is carried out. % If an error is detected, the error message shown below is displayed. Referring to the displayed message, rectify the error. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-46 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 118
downward. % Take the test chart away from the vertical size guide by 2 inches (5 cm), then push it against the horizontal size guide to load the test chart. % Place about 10 sheets value of same screen and old date AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-47 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 119
] is displayed. % If [No] is selected, the adjustment value registration screen below is displayed. Press [Return] to return to the [Density Balance Auto. Adjustment] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-48 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 120
[Maximum Density Auto Adjustment]. Be sure to perform Color Density Manual Control after changing the maximum density. This section describes how to [Maximum Density Adjustment] in sequence. 3 Press [Print Mode]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-49 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 121
-support/downloads/i/i1profiler-i1publish_v1_7_1 1 Place the paper for the maximum density management that has been decided in consultation with the service representative. 2 Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen. AccurioPress C2070/C2070P/C2060/C3080 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 122
press Start on the control panel. A chart applied the Screen 1 (Dot190 Recommended) is Output. 6 Press [Exit PrintMode] and return to the [Maximum Density Adjustment] screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-51 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 123
[Licensing] turns green. (About 1 minute) % When the registration setting screen appears, select [Register Later]. 9 Select [Advanced] in [User Mode]. 10 Select [i1Pro | i1Pro 2] in [Default display device]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-52 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 124
items 3 11 Select [Measure Chart] in [Printer] of Workflow selection. 12 Select [i1Pro] or [i1Pro2] in [Device setup]. 13 Configure [Rows per page] to [5] and [Columns per page] to [4]. 14 Click [Next]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-53 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 125
hear a beep sound, check that the read patch is displayed on the screen. For the remeasurement, click the patch that you want to measure again. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-54 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 126
to the spectrophotometer before you measure the color. 19 And then, measure K, C, M, and Y of the other patch. 20 When the measurement completes, click [Save Data]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-55 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 127
[Save]. Select [i1Profiler CGATS Custom] in Save as type. 22 In [Custom CGATS Options], configure the settings as shown below, and click [OK]. After you press [OK], 3 text files the saved text files in Excel. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-56 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 128
Compare the calculated average with the maximum density target value that the service representative has informed. When two values are same or close, end the from -5% to +10% Example: Maximum density target value AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-57 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 129
step 25 to step 30 until the maximum density is within the acceptable target density range. Acceptable target density range: Y, M, C: from -5% to +5%, K: from -5% to +10% AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-58 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 130
NOTICE Check the maximum density target value that is informed from the service representative. Perform the Maximum Density Adjustment using the paper for the maximum the Screen 1 (Dot190 Recommended) is Output. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-59 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 131
, and activate the power of FD-5BT. 8 Use the up down move button on the home screen, and move the cursor to [Sheet] or [Sample]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-60 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 132
] on the option screen, and press the OPTION button. 11 Move the cursor to [Density Options] on the menu screen, and press the OPTION button. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-61 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 133
use FD-5BT, refer to the manual supplied with the spectrophotometer. 13 Press the return button and the menu screen is displayed. 14 Move the cursor to [Calibration] on the menu screen, and press the OPTION button. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-62 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 134
. 17 Stack 10 sheets of blank paper for the maximum density management, and place the job that is output in step 5 on top of it. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-63 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 135
-5BT on the patch that you measure. When you hear a beep sound, the density of the read patch is displayed on the FD-5BT screen. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-64 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 136
format. 20 Measure all the maximum density patches of K, C, M, and Y in the same way. 21 Calculate the average of the maximum density for K, C, M, and Y each. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-65 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 137
22 Compare the calculated average with the maximum density target value that the service representative has informed. When two values are same or close, end the 006/step -M: Δ0.01/step -C: Δ0.013/step -K: Δ0.01/step AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-66 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 138
Color Density Manual Control service representative. - When Intelligent Quality Optimizer IQ-501 is mounted, [Maximum Density Auto Adjustment] is displayed. When Intelligent Quality Optimizer IQ-501 is not mounted, [Max. Density Auto Adj. (RU)] is displayed. AccurioPress C2070/C2070P/C2060/C3080 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 139
]. 4 Load paper used to register a desired density in a tray. The paper profile for the tray automatically changes to the one used for registering a desired density. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-68 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 140
for registering a desired density. % When you want to make fine-adjustment after checking the result of the automatic adjustment, manually make adjustments using the Maximum Density Adjustment in the section above. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-69 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 141
density control function (Adjustment of color sensor for each paper type / Color density manual control), always set the [Use Color Density Control] to [ON]. 1 On [Quality Adjustment] on the [Adjustment Menu]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-70 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 142
3.6 Details of quality adjustment items 3 3 Press [Color Density Control]. 4 Press [Basic Setting]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-71 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 143
control: [Standard] This function only adjusts the primary colors (CMYK). When Intelligent Quality Optimizer IQ-501 is mounted on the machine, [Precise] is always set. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-72 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 144
[Color Density Manual Control] You can manually adjust the color density. 1 On the touch panel of the main body, press [Adjustment] on the [MACHINE] screen. The [Adjustment Menu] is displayed. 2 Press [Quality Adjustment] on the [Adjustment Menu]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 145
3.6 Details of quality adjustment items 3 3 Press [Color Density Control]. 4 Press the [Color Density Manual Control] of [Expert Setting]. 5 Press [Print Mode]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-74 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 146
control panel. % To set the output tray, press [Output Setting] at the upper right of the PRINT MODE screen. 9 When the chart is output, the manual control is completed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-75 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 147
by using Color Centro, disable Color Density Control. This section explains the manual calibration using the Controller function. . Meaning and Purpose of Controller Calibration page 3-6, page 3-3, and page 3-4. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-76 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 148
creating a profile may help solve the problem. Executing Calibration Start Color Centro, and your computer beforehand. For details, refer to the instrument's manual. 2 Start Color Centro and log in to the machine AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-77 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 149
Settings] to [Screen 1] (default). Item [Paper Type] [Screen Settings] Setting [Coated GL] [Screen 1] • You do not need to change from the default set- ting, [Screen 1]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-78 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 150
using the instrument. The [Print Chart] screen is displayed. 9 On the [Print Chart] screen, set the [Copies] and [Paper Tray]. After setting, click [Print]. Example: AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-79 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 151
, Output Number of Sets, and No. are printed. 10 Connect the instrument to the computer and click [Start] on the [Execute Calibration] screen. Calibration starts. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-80 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 152
sheets of paper of the same type as the chart underneath the chart to be measured. 13 When the following message is displayed, click [OK]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-81 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 153
of quality adjustment items 3 14 Place the measurement guide plate flat on the chart. Press and hold the problem, register the calibration table. % By registering the acquired calibration data in the image controller, this data can be applied when printing. AccurioPress C2070/C2070P/C2060/C3080 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 154
two methods are available to perform Exact Color. - Manual adjustment by using Color Centro - Automatic adjustment by using the touch panel . Meaning and Purpose of Advanced Controller Calibration (Exact Color) AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-83 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 155
not improve color stability, creating a profile may resolve the problem. . Intended Environment Operating system Application Image Controller Color 's manual. 2 Start Color Centro and log in to the machine. The Color Centro top screen is displayed. AccurioPress C2070/C2070P/C2060/C3080/C3080P - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 156
] on the [Paper Type/Screen Settings] screen and click [OK]. Example: Set the [Paper Type] to [Coated GL], and the [Screen Settings] to [Screen 1] (default). AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-85 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 157
to change from the default set- ting, [Screen 1]. 7 Click [Start Calibration]. % To enable this button, disable Color Density Control. The [Execute Calibration] screen is displayed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-86 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 158
Color function starts and displays the [Operation steps] screen. 9 On the [Operation steps] screen, click [Next]. The [1. Create of current table(ExCol)] screen is displayed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-87 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 159
3.6 Details of quality adjustment items 3 10 Click [Print]. Print the color chart that is to be measured using the instrument. A test chart is printed. 11 Click [Start]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-88 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 160
[Operation steps] screen is displayed. 13 On the [Operation steps] screen, click [Next]. The [2. Accuracy Measurement(ExCol) Enhancement of a correction table(FB1)] screen is displayed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-89 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 161
printed. 15 Click [Start]. 16 Measure the chart using the instrument. After you finish the chart measurement, click [Next]. The [Operation steps] screen is displayed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-90 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 162
table is registered in the image controller. Executing Exact Color: Touch panel To use this function, mount Intelligent Quality Optimizer IQ-501 on the machine. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-91 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 163
3.6 Details of quality adjustment items 3 1 Press [Controller]. 2 Press [Color Management]. 3 Press [Exact Color]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-92 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 164
] flashes red during execution. A chart is printed up to 5 times. When processing is completed, a message is displayed. 7 Press [Close]. The result is displayed. 8 Press [OK]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-93 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 165
to perform G7 Calibration. - Manual adjustment by using Color Centro Exact Color to G7 calibration, contact your service representative. . When to perform - Any time a profile may resolve the problem. . Intended Environment Operating 101) AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 166
instrument must be installed on your computer beforehand. For details, refer to the instrument's manual. 2 Start Color Centro and log in to the machine. The Color Centro top [Instrument: i1Pro2(M1)] is displayed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-95 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 167
Settings] to [Screen 1] (default). Item [Paper Type] [Screen Settings] Setting [Coated GL] [Screen 1] • You do not need to change from the default set- ting, [Screen 1]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-96 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 168
]. The [Start G7 Calibration] screen is displayed. 8 Click [Print]. Print the color chart that is to be measured using the instrument. A test chart is printed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-97 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 169
image controller, this data can be applied when printing. 11 Click [OK] on the [Information] screen. The calibration table is registered in the image controller. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-98 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 170
Measurement of G7Calibration] screen is displayed. 13 Click [Print]. Print the color chart that is to be measured using the instrument. A test chart is printed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-99 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 171
whether the [D-Max] (maximum density) under [Measure] is in its appropriate range. Check whether the [Target] and [Density (after Calibration)] in the graph are close. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-100 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 172
for G7 calibration is printed. Executing G7 Calibration: Touch panel To use this function, mount Intelligent Quality Optimizer IQ-501 on the machine. 1 Press [Controller]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-101 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 173
Calibration]. 4 Press [Change] in [Paper Tray Setting], and select a tray. To appropriately print charts, select a tray in which the appropriate size of paper is loaded. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-102 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 174
Optimizer IQ-501. 1 Press [Adjustment] on the [MACHINE] screen to display the [Adjustment Menu] screen. 2 Press [Quality Adjustment] and [Package Color Auto Adj.] in sequence. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-103 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 175
of Adjustment Target], [Additional Adjustment], [Maximum Density Adjust- ment Tray], or [Adjustment Tray]). % You can press [Previous] or [Next] to move the page. 5 Press [Start]. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-104 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 176
3.6 Details of quality adjustment items 3 6 When the adjustment is completed, the adjustment result is displayed. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-105 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 177
3.6 Details of quality adjustment items 3 AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-106 - Konica Minolta C3080P | AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 178
© 2017 2017.11