Konica Minolta C3080P AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 55
For example, when the cross + of [1] is misaligned by 2.0 mm in the plus side in the X-axis direction
View all Konica Minolta C3080P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 55 highlights
2.5 How to Operate the Both Sides Adj. Item 2 9 Measure the gap between the guide for each of [1] to [4] in the back side (Back) and the guide in the front side (Front) of the second and third output charts. A B % "A" (black guide) in the figure indicates the front side, and "B" (blue guide) indicates the back side (for explanation, guide B is shown in blue but printed in black on the actually output test chart). % The scale resolution is 0.5 mm. % Measure the gap between the print positions in the horizontal direction (X-axis) and vertical direction (Y-axis). % You can enter a value in 0.1 mm increments. % For example, when the cross (+) of [1] is misaligned by 2.0 mm in the plus side in the X-axis direction and 1.5 mm in the minus side in the Y-axis direction compared with the front side as shown in the figure, move the blue line in the back side by 2.0 mm in the minus side in the X-axis direction and 1.5 mm in the plus side in the Y-axis direction. % Be sure to make note of the measurement values. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 2-34