Konica Minolta C3080P AccurioPress C2070/C3080 Series Daily Maintenance Guide - Page 171
CMYK Density], and Gray Step gray balance are displayed.
View all Konica Minolta C3080P manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 171 highlights
3.6 Details of quality adjustment items 3 14 Click [Start]. 15 Measure the chart using the instrument. After you finish the chart measurement, click [OK]. % When the values of ΔCh and ΔE* are not standard as the result of the accuracy check, the dialogue is displayed. You can choose to recalculate and register the calibration table to fit in the target range or register as is in the dialogue. When you recalculate, you can print the report about the current correction data before executing. % When you recalculate, you are recommended to return to Step 6 to measure the accuracy after executing. 16 Check the measurement results (CMYK density and Gray Step) on the [Calibration Manager] screen. When the calibration accuracy measurement is completed, the measurement results for CMYK density and Gray Step (gray balance) are displayed. -[CMYK Density]: Check whether the [D-Max] (maximum density) under [Measure] is in its appropriate range. Check whether the [Target] and [Density (after Calibration)] in the graph are close. AccurioPress C2070/C2070P/C2060/C3080/C3080P/C3070, AccurioPrint C2060L/C3070L 3-100