Page 41 highlights
EXPLANATION FOR MICOM CIRCUIT 1-12. Temperature compensation circuit LRSC269**** R16 R17 Temperature compensation at refrigerator Temperature compensation at freezer Freezer Resistance value (RCF1) Temperature compensation 180 kΩ +5 °C [+9°F] 56 kΩ +4 °C [+7.2°F] 33 kΩ +3 °C [+5.4°F] 18 kΩ +2 °C [+3.6°F] 12 kΩ +1 °C [+1.8°F] 10 kΩ 0 °C [0°F] 8.2 kΩ -1 °C [-1.8°F] 5.6 kΩ -2 °C [-3.6°F] 3.3 kΩ -3 °C [-5.4°F] 2 kΩ -4 °C [-7.2°F] 470 Ω -5 °C [-9°F] Refrigerator Resistance value (RCR1) Temperature compensation 180 kΩ +2.5 °C [+4.5°F] 56 kΩ +2.0 °C [+3.6°F] 33 kΩ +1.5 °C [+2.7°F] 18 kΩ +1.0 °C [+1.8°F] 12 kΩ +0.5 °C [+0.9°F] 10 kΩ 0 °C [0°F] 8.2 kΩ -0.5 °C [-0.9°F] 5.6 kΩ -1.0 °C [-1.8°F] 3.3 kΩ -1.5 °C [-2.7°F] 2 kΩ -2.0 °C [-3.6°F] 470 Ω -2.5 °C [-4.5°F] Remarks Warmer Reference temperature Cooler u Temperature compensation table by adjustment value (difference value against current temperature) Ex) If you change compensation resistance of (RCR1) from 10 kΩ (current resistance) to 18 kΩ (modified resistance), the temperature will increase by +1°C[+1.8°F]. - 41 -