23 | SPECTRAVIEW II - USER'S GUIDE Information window The Information window is accessed from the Tools menu. It will also be automatically displayed after a display calibration is completed. Note: The graphs shown in the Information window can be panned, zoomed and scaled. Click and drag to select a zoom area. Use the arrow keys to pan. Size the dialog to scale the graphs. The graphs and information can also be copied to the clipboard and pasted into other document and image editing applications by right-clicking and selecting Copy. This is useful for sharing and documenting various results Information window - Summary tab White Point The Target values are the currently selected Target's White Point. The Calibrated values show the actual measured White Point after the display has been calibrated. The Delta E value is the calculated color difference between the Target and Calibrated White Point using both the color and luminance. This is calculated using the Delta E CIE 94 color formula. A Delta E value of 1 is considered just perceptible to 50% of users. Values under 3 are generally considered excellent for display calibration.