Viewfinder displays

Page 16 highlights

Viewfinder displays Viewfinder lamp displays 1 REC BATT VTR SAVE 234 The displays shown in the example are those of the AJ-VF10. (For details on the viewfinder, refer to the operating instructions of the viewfinder available as an optional accessory.) 1 REC (record) lamp This lights up red during recording. It flashes when an error has occurred. For further details, refer to "Warning system" (page 38). 2 (irregular operation status warning) lamp This lights up when the unit is placed in an irregular operation status for any of the items set to ON in the sub-menu . For details on selecting the items subject to the lamp display, refer to sub-menu (page 37). 3 BATT (battery) lamp This starts flashing several minutes before the battery voltage drops to the level where the battery can no longer be used, and it remains lighted when the battery can no longer be used. To prevent an interruption to operation, replace the battery before the battery becomes completely discharged. For further details, refer to "Warning system" (page 38). 4 VTR SAVE (VTR power-saving) lamp This lights up when the VTR SAVE/STBY switch is set to SAVE. It goes off during recording. After the period set for the pause timer is exceeded during Rec Pause, or after 1 minute has passed during Pause (Still), the unit will automatically switch to SAVE mode and the lamp will light, regardless of the VTR SAVE/STBY switch position. Viewfinder screen status displays In addition to the images, messages indicating the unit's settings and the operation mode appear on the viewfinder screen. Also displayed are the center marker and safety zone markers. At the top, bottom and right edges of the screen are the items which have been set to ON using the sub-menu , and screens or the switches relating to the viewfinder displays. When a setting has been changed or an adjustment is made, a message informing the user of the setting details, adjustment transition status and adjustment result is displayed for about 3 seconds. For further details, refer to the items concerned on the sub-menu , , , , and screens. < 1 I EX TAPE NEAR END FLUO. = 2 iREC TCG 12:34:56:00 3 AWB+02 > 4 Z78 ? 5 ¢ 1 2 3.2K @ ATW A 7 F5.6 B 6 SPOT QUICK FOCUS 0dB C FL1 D 8 1/100 LOW LIGHT 9 DJan-01-01 23:59:00 48K CH1 CH2 ========= ¢¢¢min 13.4V E : ; G H F Status displays on the viewfinder screen when the MODE CHECK switch is ON (normal) EX TAPE NEAR END FLUO. TCG 12:34:56.00 NDF SCENE F1:FLUO. WHITE :A 3.6K KNEE :MANUAL A.IRIS:BACK GAIN :0dB GAMMA :NORMAL FILTER:1 COLOR :+10 SHUT :OFF SKIN :OFF J DJan-01-01 23:59:00 48K CH1 CH2 ========= ¢¢¢min 13.4V Status displays on the viewfinder screen when the MODE CHECK switch is ON (FULL AUTO) EX TAPE NEAR END FULL TCG 12:34:56.00 NDF SCENE F1:FLUO. FULL AUTO FILTER:1 GAMMA :NORMAL SKIN :OFF J DJan-01-01 23:59:00 48K CH1 CH2 ========= ¢¢¢min 13.4V 16

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

EX
TAPE NEAR END FLUO.
48K
CH2
iREC
TCG 12:34:56:00
0
dB
1100
LOW LIGHT
DJan-01-01 23:59:00
=========
¢¢¢
min 13.4V
Z78
ATW
F56
CH1
AWB+02
32K
.
.
SPOT
QUICK FOCUS
¢
1
¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢
¢
2
¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢
FL1
/
2
1
<
4
5
6
7
8
9
:
;
G
H
F
D
E
C
B
A
@
?
>
=
I
16
EX
TAPE NEAR END FLUO.
48K
CH2
TCG 12:34:56.00 NDF
SHUT
:OFF
SKIN
:OFF
!
¢¢¢¢¢¢¢¢¢¢¢¢
DJan-01-01 23:59:00
=========
¢¢¢
min 13.4V
WHITE :A 3.6K
KNEE
:MANUAL
A.IRIS:BACK
SCENE
F1:FLUO.
GAIN
:0dB
GAMMA :NORMAL
FILTER:1
COLOR :+10
CH1
Viewfinder displays
REC
BATT
VTR
SAVE
1
3
2
3
4
In addition to the images, messages indicating the unit’s settings
and the operation mode appear on the viewfinder screen.
Also displayed are the center marker and safety zone markers.
At the top, bottom and right edges of the screen are the items which
have been set to ON using the sub-menu <MARKER/ZEBRA>, <VF
DISPLAY 1/2> and <VF DISPLAY 2/2> screens or the switches
relating to the viewfinder displays.
When a setting has been
changed or an adjustment is made, a message informing the user
of the setting details, adjustment transition status and adjustment
result is displayed for about 3 seconds.
For further details, refer to the items concerned on the sub-menu
<MARKER/ZEBRA>, <VF DISPLAY 1/2>, <VF DISPLAY 2/2>,
<!LED>, <CAMERA ID> and <TIME DATE> screens.
J
J
The displays shown in the example are those of the AJ-VF10.
(For details on the viewfinder, refer to the operating instructions of
the viewfinder available as an optional accessory.)
1
REC (record) lamp
This lights up red during recording.
It flashes when an error has
occurred.
For further details, refer to “Warning system” (page
38).
3
BATT (battery) lamp
This starts flashing several minutes before the battery voltage
drops to the level where the battery can no longer be used, and
it remains lighted when the battery can no longer be used.
To
prevent an interruption to operation, replace the battery before
the battery becomes completely discharged.
For further details,
refer to “Warning system” (page 38).
Viewfinder lamp displays
Viewfinder screen status displays
Status displays on the viewfinder screen when the
MODE CHECK switch is ON (normal)
EX
TAPE NEAR END
FULL
48K
CH2
TCG 12:34:56.00 NDF
!
¢¢¢¢¢¢¢¢¢¢¢¢
DJan-01-01 23:59:00
=========
¢¢¢
min 13.4V
FULL AUTO
FILTER:1
SCENE
F1:FLUO.
GAMMA :NORMAL
SKIN
:OFF
CH1
Status displays on the viewfinder screen when the
MODE CHECK switch is ON (FULL AUTO)
2
(irregular operation status warning) lamp
This lights up when the unit is placed in an irregular operation
status for any of the items set to ON in the sub-menu <!LED>.
For details on selecting the items subject to the
lamp
display, refer to sub-menu <!LED> (page 37).
4
VTR SAVE (VTR power-saving) lamp
This lights up when the VTR SAVE/STBY switch is set to SAVE.
It goes off during recording.
<Note>
After the period set for the pause timer is exceeded during Rec
Pause, or after 1 minute has passed during Pause (Still), the
unit will automatically switch to SAVE mode and the lamp will
light, regardless of the VTR SAVE/STBY switch position.