Selecting the viewfinder screen display

Page 19 highlights

Viewfinder displays Display item What is displayed G Calendar/clock status D switching display H Remaining ¢¢¢min tape/recording inhibit = END display = INH IND+003 I Safety zone markers J Cause of !LED lighting display (this item appears only during a MODE check) Corner: 3 types Box: 3 types 16:9 full box: 3 types SUPER-V EXT ON FIL No1 FIL wo No1 FIL NG SHUT wo 1/100 SHUT ON WHITE ATW WHITE PRE GAIN wo 0dB Status causing the display to appear "D" is displayed only when a VF DISPLAY setting has been selected. This is to enable the user to differentiate between the screen displays when "TIME+DATE" (see page 36) has been selected as the TIME/DATE setting on and when "REC" has been selected as the TIME STAMP setting (see page 34) on . Normally, "¢¢¢min" is lighted, and it flashes when the tape is nearly at its end. When the tape reaches the end, "= END" lights. When recording is inhibited, "= INH" lights. This lights during an INDEX search. A positive number denotes an index count in the forward direction, and a negative number denotes an index count in the reverse direction. With each detection, the value is decremented to zero, and when the tape stops, the remaining tape display is restored. The safety zone markers selected for 01 through 09 in SAFETY ZONE are displayed. For further details, refer to the table for "SAFETY ZONE" (page 35) on the sub-menu. Displayed when SUPER-V is set to ON. Displayed when EXTENDER is set to ON. Displayed when FILTER is set to 1. Displayed when FILTER is set to a number other than 1. Displayed when FILTER is set to NG. Displayed when SHUTTER is set to a speed other than 1/100. Displayed when SHUTTER is set to ON. Displayed when ATW has been selected for AWB. Displayed when the AWB switch has been set to PRE. Displayed when a gain value other than 0 dB has been selected. Selecting the viewfinder screen display Status displayed when the corresponding status is established Display/nondisplay selected by MARKER/ZEBRA 1 Extender display ≤ - 2 INTERVAL REC status display ≤ - 3 Time code display - - 4 Center marker - ≤ 5 Message display ≤ - 6 IRIS MODE switch status display ≤ - 7 QUICK FOCUS display ≤ - 8 Shutter speed display ≤ - 9 LOW LIGHT warning display ≤ - : AUDIO sampling frequency display - - ; Audio level meter display - - < VTR warning display/voltage warning display ≤ - = FULL AUTO/SCENE FILE display ≤ - > AWB color temperature fine adjustment amount display ≤ - ? Zoom display - - @ AWB color temperature display - - A ATW, AWB channel display - - B F value display - - C Gain display - - D Filter display - - E Calendar/clock display - - F Voltage display, BAR display - - G Calendar/clock status switching display ≤ - H Remaining tape/recording inhibit display - - I Safety zone markers - ≤ Display/nondisplay selected by VF DISPLAY 1/2 or 2/2 Displayed and can be cleared Displayed during playback 19

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44

19
Viewfinder displays
Display item
What is displayed
Status causing the display to appear
J
Cause of !LED
lighting display
(this item appears
only during a MODE
check)
SUPER-V
EXT ON
FIL No1
FIL wo No1
FIL NG
SHUT wo 1/100
SHUT ON
WHITE ATW
WHITE PRE
GAIN wo 0dB
Displayed when SUPER-V is set to ON.
Displayed when EXTENDER is set to ON.
Displayed when FILTER is set to 1.
Displayed when FILTER is set to a number other than 1.
Displayed when FILTER is set to NG.
Displayed when SHUTTER is set to a speed other than 1/100.
Displayed when SHUTTER is set to ON.
Displayed when ATW has been selected for AWB.
Displayed when the AWB switch has been set to PRE.
Displayed when a gain value other than 0 dB has been selected.
G
Calendar/clock status
switching display
D
“D” is displayed only when a VF DISPLAY setting has been selected.
This is
to enable the user to differentiate between the screen displays when
“TIME+DATE” (see page 36) has been selected as the TIME/DATE setting
on <VF DISPLAY 2/2> and when “REC” has been selected as the TIME
STAMP setting (see page 34) on <VTR OPTION>.
H
Remaining
tape/recording inhibit
display
¢¢¢
min
=
END
=
INH
Normally, “
¢¢¢
min” is lighted, and it flashes when the tape is nearly at its end.
When the tape reaches the end, “
=
END” lights.
When recording is inhibited, “
=
INH” lights.
IND+003
This lights during an INDEX search.
A positive number denotes an index
count in the forward direction, and a negative number denotes an index
count in the reverse direction.
With each detection, the value is
decremented to zero, and when the tape stops, the remaining tape display is
restored.
I
Safety zone markers
Corner:
3 types
Box:
3 types
16:9 full box: 3 types
The safety zone markers selected for 01 through 09 in SAFETY ZONE are
displayed.
For further details, refer to the table for “SAFETY ZONE” (page
35) on the <MARKER/ZEBRA> sub-menu.
1
Extender display
2
INTERVAL REC status display
3
Time code display
4
Center marker
5
Message display
6
IRIS MODE switch status display
7
QUICK FOCUS display
8
Shutter speed display
9
LOW LIGHT warning display
:
AUDIO sampling frequency display
;
Audio level meter display
<
VTR warning display/voltage warning display
=
FULL AUTO/SCENE FILE display
>
AWB color temperature fine adjustment amount display
?
Zoom display
@
AWB color temperature display
A
ATW, AWB channel display
B
F value display
C
Gain display
D
Filter display
E
Calendar/clock display
F
Voltage display, BAR display
G
Calendar/clock status switching display
H
Remaining tape/recording inhibit display
I
Safety zone markers
Selecting the viewfinder screen display
Status displayed
when the
corresponding
status is
established
Display/non-
display selected
by
MARKER/ZEBRA
Display/non-
display selected
by VF DISPLAY
1/2 or 2/2
Displayed and
can be cleared
Displayed
during playback