http://tsn.pstc.panasonic.com/viewing/NA/CT-36SL13G/SVC/s1404000000.html r R DR 07 FF r B DR 07 FF PROCEDURE 1. Connect the oscilloscope to KG (CRT-Board). 2. In service mode for making electronic adjustment, select "BRIGH" DAC to obtain 2.0±0.05V DC. 3. Press RECALL button on the remote control to collapse the raster. (service SW). 4. Connect oscilloscope to KG on C-Board and adjust service mode "CUT-G" DAC until 170±2V above DC ground is measured 5. Remove the probe from KG. 6. Turn screen clockwise slowly until color is slightly appeared. 7. Then adjust "CUT R" and "CUT B" until line becomes white. 8. Press RECALL button on the remote to restore the raster. 9. Adjust "R DR" and "B DR" so the white seems like white and black like black. 10. Apply a normal signal and confirm that the image is normal and a good gray scale 11. If correction is needed perform minor touch-up method. http://tsn.pstc.panasonic.com/viewing/NA/CT-36SL13G/SVC/s1404000000.html (2 of 3)05.12.2008 0:02:52