4.1 Troubleshooting 4.1.2 Connection Can you dial an extension? Telephone cord connecting the PBX and a proprietary telephone (PT): CAUSE SOLUTION No The T/R pins are connected to the H/L Use the correct cord (the pins. inner 2 wires are for T/R and H H the outer 2 wires are for H/L). T T R R L L PBX Extension Telephone cord connecting the PBX and a single line telephone (SLT): CAUSE The T/R pins are connected to the H/L pins. H T T R R L PBX Extension SOLUTION Use the correct cord (the inner 2 wires are for T/R). Yes Telephone cord connecting the PBX and an SLT that is polarity-sensitive: CAUSE The T and R pins are crossed over. H T R L PBX T R Extension SOLUTION Reverse the connections of the T/R pins. Can you dial out using an outside (CO) line? Telephone cord connecting an outside (CO) line and the PBX: CAUSE The outside (CO) line(s) is connected to the H/L pins. No T R SOLUTION Reconnect the outside (CO) line(s) to the T/R pins of the telephone jack using 2-conductor wiring. Outside (CO) Line PBX Installation Manual 81