Panasonic PTDZ8700U PTDS8500U User Guide - Page 115

Control commands via LAN, When WEB Control administrator rights password is set Protect mode

Page 115 highlights

Technical Information Control commands via LAN JJWhen WEB Control administrator rights password is set (Protect mode) 1111 Obtain the IP address and port number (Initial set value = 1024) of the projector and make a request for connection to the projector. You can obtain both IP address and port number from the menu screen of the projector. IP address : Obtain from MAIN MENU ⇒ [NETWORK] ⇒ [NETWORK STATUS] Port No. : Obtain from MAIN MENU ⇒ [NETWORK] ⇒ [NETWORK CONTROL] ⇒ [COMMAND PORT] 2222 There is a response from the projector. Response data Data section "NTCONTROL" (ASCII string) 9 bytes Blank ' ' 0x20 1 byte Mode '1' 0x31 1 byte Blank ' ' 0x20 1 byte Random number section "zzzzzzzz" (ASCII code hexadecimal number) 8 bytes Termination symbol (CR) 0x0d 1 byte Mode : 1 = Protect mode 3333 Generate a 32-byte hash value from the following data using MD5 algorithm. "xxxxxx:yyyyy:zzzzzzzz" xxxxxx : yyyyy : zzzzzzzz : Administrator rights user name for WEB CONTROL (Default user name is "admin1") Password of above administrator rights user (Default password is "panasonic") 8-byte random number obtained in Step 2) Transmit using the following command format. Transmitted data Header Hash value (See above ) 32 bytes '0' 0x30 1 byte '0' 0x30 1 byte Receive data Header '0' 0x30 1 byte '0' 0x30 1 byte Error response "ERR1" "ERR2" "ERR3" "ERR4" "ERR5" "ERRA" Error message Undefined control command Out of parameter range Busy state or no-acceptable period Timeout or no-acceptable period Wrong data length Password mismatch 4 bytes Data section Control command (ASCII string) Undefined length Termination symbol (CR) 0x0d 1 byte Data section Control command (ASCII string) Undefined length Termination symbol (CR) 0x0d 1 byte Termination symbol (CR) 0x0d 1 byte Appendix ENGLISH - 115

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105
  • 106
  • 107
  • 108
  • 109
  • 110
  • 111
  • 112
  • 113
  • 114
  • 115
  • 116
  • 117
  • 118
  • 119
  • 120
  • 121
  • 122
  • 123
  • 124
  • 125
  • 126
  • 127
  • 128
  • 129

Technical Information
ENGLISH -
115
Appendix
Control commands via LAN
J
When WEB Control administrator rights password is set (Protect mode)
<Connection method>
Obtain the IP address and port number (Initial set value = 1024) of the projector and
1 )
make a request for connection to the projector.
You can obtain both IP address and port number from the menu screen of the projector.
IP address
:
Obtain from MAIN MENU
[NETWORK]
[NETWORK STATUS]
Port No.
:
Obtain from MAIN MENU
[NETWORK]
[NETWORK CONTROL]
[COMMAND PORT]
There is a response from the projector.
2 )
Response data
Data section
Blank
Mode
Blank
Random number
section
Termination
symbol
“NTCONTROL”
(ASCII string)
‘ ’
0x20
‘1’
0x31
‘ ’
0x20
“zzzzzzzz”
(ASCII code hexadecimal
number)
(CR)
0x0d
9 bytes
1 byte
1 byte
1 byte
8 bytes
1 byte
Mode : 1 = Protect mode
Generate a 32-byte hash value from the following data using MD5 algorithm.
3 )
“xxxxxx:yyyyy:zzzzzzzz”
xxxxxx
:
Administrator rights user name for WEB CONTROL
(Default user name is “admin1”)
yyyyy
:
Password of above administrator rights user
(Default password is “panasonic”)
zzzzzzzz
:
8-byte random number obtained in Step 2)
<Command transmission method>
Transmit using the following command format.
Transmitted data
Header
Data section
Termination
symbol
Hash value
(See above
<Connection method>)
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
32 bytes
1 byte
1 byte
Undefined length
1 byte
Receive data
Header
Data section
Termination
symbol
‘0’
0x30
‘0’
0x30
Control command
(ASCII string)
(CR)
0x0d
1 byte
1 byte
Undefined length
1 byte
Error response
Error message
Termination symbol
“ERR1”
“ERR2”
“ERR3”
“ERR4”
“ERR5”
“ERRA”
Undefined control command
Out of parameter range
Busy state or no-acceptable period
Timeout or no-acceptable period
Wrong data length
Password mismatch
(CR)
0x0d
4 bytes
1 byte