Panasonic WVNP1004 WVNP1004 User Guide - Page 30

Con the alarm settings [Alarm setup]

Page 30 highlights

Configure the alarm settings [Alarm setup] The settings relating to alarm occurrences such as settings for the alarm action at an alarm occurrence, the alarm occurrence notification, and the VMD area settings can be configured on this page. The "Alarm setup" page has 3 tabs of the [Alarm] tab, the [VMD area] tab and the [Notification] tab. Configure the settings relating to the alarm action [Alarm] Click the [Alarm] tab on the "Alarm setup" page. The settings relating to the alarm action can be configured on this page. Refer to pages 31 and 32 for further information about the settings relating to the alarm image and the alarm out connector. [Originating port number] Select a port number to be used to receive the command alarm. Available port number: 1 - 65535 Default: 8181 [Scene change detection alarm] Select "ON" or "OFF" to determine whether or not to perform the alarm action when the camera lens is covered by something such as a cloth, or when the shooting direction of the camera is moved. Default: OFF [Terminal alarm] Select "ON" or "OFF" to determine whether or not to receive the terminal alarm. Default: OFF [Level setup] Select the sensitivity of the scene change detection alarm function from the following. Level 1/Level 2/Level 3 Default: Level 1 [VMD alarm] Select "ON" or "OFF" to determine whether or not to perform the alarm action using the VMD function. Refer to page 33 for further information about the VMD area settings. Default: OFF [Command alarm] Select "ON" or "OFF" to determine whether or not to receive the command alarm. The command alarm is the function that notifies of Panasonic protocol alarm from the other cameras. When "ON" is selected, alarm actions will be performed between multiple cameras. Default: OFF 30

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73

30
Configure the alarm settings [Alarm setup]
The settings relating to alarm occurrences such as settings for the alarm action at an alarm occurrence, the alarm
occurrence notification, and the VMD area settings can be configured on this page.
The "Alarm setup" page has 3 tabs of the [Alarm] tab, the [VMD area] tab and the [Notification] tab.
Configure the settings relating to the alarm action [Alarm]
Click the [Alarm] tab on the "Alarm setup" page.
The settings relating to the alarm action can be configured on this page. Refer to pages 31 and 32 for further infor-
mation about the settings relating to the alarm image and the alarm out connector.
[Terminal alarm]
Select "ON" or "OFF" to determine whether or not to
receive the terminal alarm.
Default:
OFF
[VMD alarm]
Select "ON" or "OFF" to determine whether or not to
perform the alarm action using the VMD function. Refer
to page 33 for further information about the VMD area
settings.
Default:
OFF
[Command alarm]
Select "ON" or "OFF" to determine whether or not to
receive the command alarm.
The command alarm is the function that notifies of
Panasonic protocol alarm from the other cameras.
When "ON" is selected, alarm actions will be performed
between multiple cameras.
Default:
OFF
[Originating port number]
Select a port number to be used to receive the com-
mand alarm.
Available port number:
1 - 65535
Default:
8181
[Scene change detection alarm]
Select "ON" or "OFF" to determine whether or not to
perform the alarm action when the camera lens is cov-
ered by something such as a cloth, or when the shoot-
ing direction of the camera is moved.
Default:
OFF
[Level setup]
Select the sensitivity of the scene change detection
alarm function from the following.
Level 1/Level 2/Level 3
Default:
Level 1