    UK5 Specification of expanding serial command Specification of Expanding serial command UK5 Ver 1.0 Pub Issued March 01 2010 Item Page Ver.1 Rev. B Page 1
  • Sanyo CE42LH2WP | IR Command List - Page 2
    UK5 Specification of expanding serial command TITLE Specification of Expanding serial command (Public Version) ISSUED SECT. DS Development section 1 MODEL UK5 REVISIONS Ver. CHANGE DOCUMENT DRAWN DATE CHECK DATE APPRO. DATE 1.04 Pub Fit to Japanese Ver.1.04 Fukushima 2010/3/1 Item Page
  • Sanyo CE42LH2WP | IR Command List - Page 3
    UK5 Specification of expanding serial command Contents 1. Overview ...7 2. Serial Interface Specification ...7 2.1. Transfer Specification...7 2.2. Connection ...7 3. Notes for Communication ...8 4. Notes for explanation...8 5. Functional Execution Command 9 5.1. Image control Command...9 5.2. PC
  • Sanyo CE42LH2WP | IR Command List - Page 4
    UK5 Specification of expanding serial command 8.9. Sound control Command 22 8.9.1. CF_VOLUME Command 22 8.9.2. CF_MUTE Command...23 8.10. Setting control Command 23 8.10.1. CF_LANG Command 23 8.10.2. CF_P-MANE Command 23 8.10.3. CF_FDEFAULT Command 23 8.10.4. CF_TILE Command ...24 8.10.5.
  • Sanyo CE42LH2WP | IR Command List - Page 5
    UK5 Specification of expanding serial command 9.4.9. CR_WBAL-B Command 35 9.4.10. CR_NZRED Command 35 9.4.11. CR_FILM Command ...36 9.4.12. CR_IMAGE Command 36 9.4.13. CR_DCDI Command...36 9.4.14. CR_ACCACM Command 36 9.4.15. CR_CCS Command...37 9.4.16. CR_MPEGNR Command 37 9.5. PC control Read
  • Sanyo CE42LH2WP | IR Command List - Page 6
    UK5 Specification of expanding serial command 4 10. Specification Command with address 50 10.1. Outline...50 10.2. Functional execute command with address 50 10.2.1. Format...50 10.2.2. Sequential execution function 51 10.3. Status read command with address 51 10.3.1. Format...51 Item Page Ver
  • Sanyo CE42LH2WP | IR Command List - Page 7
    UK5 Specification of expanding serial command 1. Overview 1. 1 This specification define MONITOR SET control commands for UK5 chassis products communicating with LD-Net. 1. 2 These control commands are originally developed for the communication with LD-Net, but also can be used to control a MONITOR
  • Sanyo CE42LH2WP | IR Command List - Page 8
    UK5 Specification of expanding serial command 3. Notes for Communication 3.1 The MONITOR SET command is defined one command/one line that starts with "C" and ends with carriage return (0x0D). 3.2 There are two types of commands, Functional Execution Commands and Status Read Commands. [Example
  • Sanyo CE42LH2WP | IR Command List - Page 9
    UK5 Specification of expanding serial command 5. Functional Execution Command 5. . Image control Command Execute command CF_BRIGHT_%1[CR] CF_CONT_%1[CR] CF_COLOR_%1[CR] CF_TINT_%1[CR] CF_SHARP_%1[CR] CF_WBAL[CR] CF_WBAL-R_%1[CR] CF_WBAL-G_%1[CR] CF_WBAL-B_%1[CR] CF_NZRED_%1[CR] CF_FILM_%1[CR]
  • Sanyo CE42LH2WP | IR Command List - Page 10
    UK5 Specification of expanding serial command 5. . Setting control Command CF_LANG_%1[CR] CF_P-MANE_%1[CR] CF_FDEFAULT_%1[CR] CF_TILE_%1[CR] CF_TILE-HSETS_%1[CR] CF_TILE-VSETS_%1[CR] CF_TILE-HLOCAT_%1[CR] CF_TILE-VLOCAT_%1[CR] CF_TILE-BZLHADJ_%1[CR] CF_TILE-BZLVADJ_%1[CR] CF_ONPROG_%1[CR]
  • Sanyo CE42LH2WP | IR Command List - Page 11
    UK5 Specification of expanding serial command 5. . BASIC Command Basic Command No. Command Item Comment c1 C00 c2 C01 c3 C22 c4 C23 c5 C24 c6 C25 c7 C26 c8 C27 c9 C28 c10 C29 c11 C0F c12 C10 c13 C30 c14 C70 c15 C71 c16 C72 c17 C73 c18 C74 c19 C75 c20 C76
  • Sanyo CE42LH2WP | IR Command List - Page 12
    UK5 Specification of expanding serial command 6. Read Command Table 6. 1 Image control Read Command Table Status read command CR_BRIGHT[CR] CR_CONT[CR] CR_COLOR[CR] CR_TINT[CR] CR_SHARP[CR] CR_WBAL[CR] CR_WBAL-R[CR] CR_WBAL-G[CR] CR_WBAL-B[CR] CR_NZRED[CR] CR_FILM[CR] CR_IMAGE[CR] CR_DCDI[CR]
  • Sanyo CE42LH2WP | IR Command List - Page 13
    UK5 Specification of expanding serial command 6. 7 Sound control Read Command Table Status read command CR_VOLUME[CR] CR_MUTE[CR] Item Status of volume value. Status of MUTE. 6. 8 Setting Read Command Table Status read command CR_LANG[CR] CR_P-MANE[CR] CR_TILE[CR] CR_TILE-HSETS[CR] CR_TILE-
  • Sanyo CE42LH2WP | IR Command List - Page 14
    UK5 Specification of expanding serial command 7 Error code Table Error code Receiving the data that cannot be decoded The wrong indication of parameter Wrong figured number, or wrong word is included. Normal receiving no error If the command of out of range is directly entered valuable parameter.
  • Sanyo CE42LH2WP | IR Command List - Page 15
    UK5 Specification of expanding serial command Functional Execution Command .1 Format PC issues a command in format as below. "CF_ Command " [CR] "CF_ Command _ " %1 [CR] "CF_ " means header, Command means the line of character, %1 means parameter "_" menas space (Stop of Command / Parameter) Monitor
  • Sanyo CE42LH2WP | IR Command List - Page 16
    UK5 Specification of expanding serial command 8 4 Image control Command 8. 4. 1 CF_BRIGHT Command Command " "[CR] " " Direct command of Bright setting. Detail Set Bright in user control. Available only normal Power ON condition. Status Receiving OK Receiving NG " "[CR] "Error code"[CR]
  • Sanyo CE42LH2WP | IR Command List - Page 17
    UK5 Specification of expanding serial command 8. 4. 6 CF_WBAL Command Command " "[CR] " " " " " "" "" Set Warm in White balance mode Set Warm in White balance mode " Set STANDARD in White balance mode " Set Personal in White balance mode Select Order of Warm → Cool → Standard → Personal →
  • Sanyo CE42LH2WP | IR Command List - Page 18
    UK5 Specification of expanding serial command 8. 4. 9 CF_FILM Command Command " "[CR] " " "" "" "" Release Film mode Select Film mode Switch upward Switch downward Detail Release Film mode. Available only normal Power ON condition. Status Receiving OK Receiving NG " "[CR] "Error code
  • Sanyo CE42LH2WP | IR Command List - Page 19
    UK5 Specification of expanding serial command 8. 4. 13 CF_CCS Command Command " "[CR] " " " " " "" "" Set up CCS to OFF. Set up CCS to Auto. " Set up CCS to Standard. Switch upward Switch downward Detail Release CCS setup Available only normal Power ON condition. Status Receiving
  • Sanyo CE42LH2WP | IR Command List - Page 20
    UK5 Specification of expanding serial command 8. 5. 3 CF_CLOCK Command Command " "[CR] " " Direct assignment of value of Horizontal position. " " is maximum value, and is indicate current Total Dots Display Area H. Detail Set up Clock of PC input signal. Available only normal Power ON
  • Sanyo CE42LH2WP | IR Command List - Page 21
    UK5 Specification of expanding serial command 8. 6. 2 CF_SOURCE Command Command " "[CR] " " Input is selected AV2 " " " " "" Select Y,Pb/Cb,Pr/Cr Select RGBHV Change forward Change backward Detail Select source of AV2 Input Available only normal Power ON condition. If assigned does
  • Sanyo CE42LH2WP | IR Command List - Page 22
    UK5 Specification of expanding serial command 8. 7 Screen control Command 8. 7. 1 CF_SCREEN Command Command " "[CR] " " Select Natural mode " " Select Normal mode " " Select Full mode " " Select Zoom16:9 mode " " Select Title16:9 mode " " Select Zoom14:9 mode " " Select
  • Sanyo CE42LH2WP | IR Command List - Page 23
    UK5 Specification of expanding serial command 8. 9. 2 CF_MUTE Command Command " "[CR] "" " " Select MUTE Select MUTE Detail Control MUTE Available only normal Power ON condition. Status Receiving OK Receiving NG " "[CR] "Error code"[CR] 8. 10 setting control Command 8. 10. 1 CF_LANG
  • Sanyo CE42LH2WP | IR Command List - Page 24
    UK5 Specification of expanding serial command 8. 10. 4 CF_TILE Command Command " "" " " "" "" "[CR] Set Tile mode Release Tile mode Change forward On → Off → On → Change backward On → Off → On → Detail Status UP DN is the same operation as On Off selection,. SET AND RELEASE Tile mode
  • Sanyo CE42LH2WP | IR Command List - Page 25
    UK5 Specification of expanding serial command 8. 10. 7 CF_TILE HLOCAT Command Command " T "[CR] " "" "" " Assign the order of Tile mode in row Change order upward 1 → 2 → 3 → Change order backward 1 → 5 → 4 → Detail Set up the number of row for Tile mode Available only normal Power ON
  • Sanyo CE42LH2WP | IR Command List - Page 26
    UK5 Specification of expanding serial command 8. 10. 11 CF_ON PROG Command Command " "[CR] " " Release On Program " " AV1 is selected after Power is On " " RGB is selected after Power is On " " AV2 is selected after Power is On " " AV3 is selected after Power is On " " DVI is selected
  • Sanyo CE42LH2WP | IR Command List - Page 27
    UK5 Specification of expanding serial command 8. 10. 14 CF_LED LIGHT Command Command " "[CR] "" " " "" "" Since On Set up LED light ON Set up LED light OFF Select forward On → Off → On → Select backward On → Off → On → Off are selectable, UP DN is the same operation. Detail Set up LED
  • Sanyo CE42LH2WP | IR Command List - Page 28
    UK5 Specification of expanding serial command 8. 10. 17 CF_RCINHIBITION Command Command " "[CR] "" " " Set up RC inhibit ON Set up RC inhibit OFF Detail Set up RC inhibit ON/OFF Available only normal Power ON condition. Receiving RC inhibit ON command while RC inhibit ON is effective, the
  • Sanyo CE42LH2WP | IR Command List - Page 29
    UK5 Specification of expanding serial command 8.12 BASIC Command Basic Command 8. 12. 1 POWER ON Command Command "C00" [CR] Detail Power ON. When already Power ON, no operation is necessary. Acceptable Response [ACK] [CR] Unacceptable "?" [CR] 8.12. 2 POWER OFF Command Command "C01" [CR]
  • Sanyo CE42LH2WP | IR Command List - Page 30
    UK5 Specification of expanding serial command 8. 12. 7 Wide "Title in 16:9" direct Command Command "C26" [CR] Detail Set wide mode to "Title in 16:9" directly. When PC mode or AV2 RGBHV mode, no operation is necessary. Acceptable Response [ACK] [CR] Unacceptable "?" [CR] 8. 12. 8 Wide "Zoom
  • Sanyo CE42LH2WP | IR Command List - Page 31
    UK5 Specification of expanding serial command 8. 12. 13 AV1 direct Command Command "C70" [CR] Detail Select "AV1" mode directly. Acceptable Response [ACK] [CR] Unacceptable "?" [CR] 8. 12. 14 RGB direct Command "C71" [CR] Detail Select "RGB" mode directly. Acceptable Response [ACK] [CR]
  • Sanyo CE42LH2WP | IR Command List - Page 32
    UK5 Specification of expanding serial command 8. 12. 19 PC direct Command Command "C76" [CR] Detail Select "PC" mode directly. Acceptable Response [ACK] [CR] Unacceptable "?" [CR] 8. 12. 20 PC Auto adjust Command Command "C64" [CR] Detail Execute PC Auto adjust function. Acceptable
  • Sanyo CE42LH2WP | IR Command List - Page 33
    UK5 Specification of expanding serial command 8. 12. 25 Child lock OFF Command Command "CF CLOK OFF" [CR] Detail Set child lock to "OFF". Acceptable Response [ACK] [CR] Unacceptable "?" [CR] 8. 12. 26 RC Inhibitions ON Command Command "CF DEA RMCY" [CR] Detail Set RC inhibition to "OFF".
  • Sanyo CE42LH2WP | IR Command List - Page 34
    UK5 Specification of expanding serial command 9.4 Image Control Read Command 9. 4. 1 CR_BRIGHT Command Command " R "[CR] Detail Read the value of Bright in user control Receiving OK " "[CR] Status " "" " Receiving NG " "[CR] 9. 4. 2 CR_CONT Command Command " R "[CR] Detail Read the
  • Sanyo CE42LH2WP | IR Command List - Page 35
    UK5 Specification of expanding serial command 9. 4. 6 CR_WBAL Command Command " R "[CR] Detail Read the status of White balance mode Receiving OK " "[CR] Status " " " " " " " " Receiving NG " "[CR] White balance mode Warm White balance mode Cool White balance mode Standard White
  • Sanyo CE42LH2WP | IR Command List - Page 36
    UK5 Specification of expanding serial command 9. 4. 11 CR_FILM Command Command " R "[CR] Detail Read the status of Film mode Receiving OK " "[CR] Status Receiving NG " " "" Release Film mode Set up Film mode "Error code"[CR] 9. 4. 12 CR_IMAGE Command Command " R "[CR] Detail Read
  • Sanyo CE42LH2WP | IR Command List - Page 37
    UK5 Specification of expanding serial command 9. 4. 15 CR_CCS Command Command " R "[CR] Detail Read the status of CCS Receiving OK " Status " " " " " Receiving NG " "[CR] "[CR] " Set up CCS OFF Set up CCS Auto Set up CCS Standard 9. 4. 16 CR_MPEGNR Command Command " R "[CR] Detail
  • Sanyo CE42LH2WP | IR Command List - Page 38
    UK5 Specification of expanding serial command 9. 5 PC control Read Command 9. 5. 1 CR_H-POS Command Command " R "[CR] Detail Read the value of Horizontal position Receiving OK " "[CR] Status Receiving NG " "" " "Error code"[CR] " "[CR] Not acceptable Unknown Command is Received 9. 5.
  • Sanyo CE42LH2WP | IR Command List - Page 39
    UK5 Specification of expanding serial command 9. 6 Video Read Command 9. 6. 1 CR_SERSYS Command Command " R "[CR] Detail Read system what now receiving Selected system is read Auto mode Receiving OK " "[CR] Status " " " " " " " " " " " " " " Receiving NG " "[CR] " "[CR]
  • Sanyo CE42LH2WP | IR Command List - Page 40
    UK5 Specification of expanding serial command 9. 7. 3 CR_SYSTEM Command Command " R "[CR] Detail Read the selecting System Receiving OK " "[CR] Status AV1, AV3 are selected " " Auto is selected " " NTSC is selected " " NTSC4.43 is selected " " PAL is selected " " SECAM is
  • Sanyo CE42LH2WP | IR Command List - Page 41
    UK5 Specification of expanding serial command 9. 8 Screen control Read Command 9. 8. 1 CR_SCREEN Command Command " R "[CR] Detail Read screen size selected (Displayed Receiving OK " "[CR] Status " " " " " " " " "FULL-ALL" " " " " " " Receiving NG "Error code"[CR] " "[CR]
  • Sanyo CE42LH2WP | IR Command List - Page 42
    UK5 Specification of expanding serial command 9. 10 Sound Control Read Command 9. 10. 1 CR_VOLUME Command Command " R "[CR] Detail Read the value of Volume in user control Receiving OK " "[CR] Status " "" " Receiving NG " "[CR] 9. 10. 2 CR_MUTE Command Command " R "[CR] Detail Read
  • Sanyo CE42LH2WP | IR Command List - Page 43
    UK5 Specification of expanding serial command 9. 11. 3 CR_TILE Command Command " "[CR] Detail Read the status ON or OFF of Tile mode Receiving OK " "[CR] Status "" Set up Tile mode ON " " Set up Tile mode OFF Receiving NG "Error code"[CR] 9. 11. 4 CR_TILE-HSETS Command Command " "[CR
  • Sanyo CE42LH2WP | IR Command List - Page 44
    UK5 Specification of expanding serial command 9. 11. 8 CR_TILE-BZLHADJ Commands Command " "[CR] Detail Read the size of bezel (Horizontal) on Tile mode Receiving OK " "[CR] Status " "" " Receiving NG " "[CR] 9. 11. 9 CR_TILE-BZLVADJ Command Command " "[CR] Detail Read the size of
  • Sanyo CE42LH2WP | IR Command List - Page 45
    UK5 Specification of expanding serial command 9. 11. 12 CR_PANELPROTECT Command Command " "[CR] Detail Read the status of Panel protect Receiving OK " "[CR] Status "" Set up Panel protect ON " " Set up Panel protect OFF Receiving NG "Error code"[CR] 9. 11. 13 CR_LEDLIGHT Command
  • Sanyo CE42LH2WP | IR Command List - Page 46
    UK5 Specification of expanding serial command 9. 12 Other Read Command 9. 12. 1 CR_STATUS Command Command " "[CR] Detail Read the status of monitor The content is the same as Basic Command" ", but it contains Error code. Receiving OK " "[CR] Status " "= Power ON " "= Power fault " "=
  • Sanyo CE42LH2WP | IR Command List - Page 47
    UK5 Specification of expanding serial command 9. 12. 5 CR_TEMP Command Command " "[CR] Detail Read current thermal status in the monitor If there are multiple thermal sensors, all thermal data can be acquired Receiving OK " "[CR] Temperature of sensor Temperature of sensor Temperature of
  • Sanyo CE42LH2WP | IR Command List - Page 48
    UK5 Specification of expanding serial command 9. 13. BASICRead Command 9. 13. 1 Power status Read Command Command "CR0" [CR] Detail Read selected Input No. Acceptable "%1" [CR] "00" = Power ON. "10" = Power error. Response %1 "20" = Standby. "40" = Power save. "80" = Set Error
  • Sanyo CE42LH2WP | IR Command List - Page 49
    UK5 Specification of expanding serial command 9. 13. 5 Signal status Read Command (Same as 9.12.3) Command "CR SIGNAL" [CR] Detail Read the signal status. Acceptable "%1" [CR] Response %1 "000 YES" = No signal "000 NO" = Signal exists. Unacceptable "%1" [CR] 9. 13. 6 Child lock setting
  • Sanyo CE42LH2WP | IR Command List - Page 50
    UK5 Specification of expanding serial command 9. 13. 10 Model number Read Command Command "CR MDL" [CR] Detail Read the Model number Acceptable "%1" [CR] "000 **********" Response %1 is model number. Maximum length of model number is 10 characters. Unacceptable "?" [CR] 10.
  • Sanyo CE42LH2WP | IR Command List - Page 51
    UK5 Specification of expanding serial command 10. 2. 2 Sequential execution functions The function needed sequential command, the same control as remote control Receiving. That is 1. Sending command every in 100 second 2. Receiving a command, execute function sequentially within 120 s. 3. Receiving
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51

UK5 Specification of expanding serial command
Item
Page
Ver.1
Rev. B
Page
1
Specification of Expanding serial command
UK5
Ver 1.0
γΈ²
Pub
Issued March 01 2010