Sanyo PLC-HF10000L RS232 Expand - Page 31

CF_PCSTORE Command, 5.10 CF_PCMODEFREE Command

Page 31 highlights

PLC-HF10000L Expand Serial Command Functional Specifications 8.5.9 CF_PCSTORE Command Command "CF_PCSTORE_%1" [CR] "MODE1 Store current PC Adjust status to Mode1 "MODE2 Store current PC Adjust status to Mode2 "MODE3 Store current PC Adjust status to Mode3 "MODE4 Store current PC Adjust status to Mode4 %1 "MODE5 Store current PC Adjust status to Mode5 "MODE6 Store current PC Adjust status to Mode6 "MODE7 Store current PC Adjust status to Mode7 "MODE8 Store current PC Adjust status to Mode8 "MODE9 Store current PC Adjust status to Mode9 "MODE10 Store current PC Adjust status to Mode10 Details Store current value of PC Adjust (each parameter status such as Total dots) to Mode1-10. This command operates the same way as storing to Mode1-10 in PC Adjust Menu. (Available only in the normal Power ON status) Response Acceptable Unacceptable "000" [CR] "101" [CR] --- When input is Video signal --- When input is no signal 8.5.10 CF_PCMODEFREE Command Command "CF_PCMODEFREE_%1" [CR] "MODE1 Set Mode1 to Free status "MODE 2 Set Mode2 to Free status "MODE 3 Set Mode3 to Free status "MODE 4 Set Mode4 to Free status %1 "MODE 5 Set Mode5 to Free status "MODE 6 Set Mode6 to Free status "MODE 7 Set Mode7 to Free status "MODE 8 Set Mode8 to Free status "MODE 9 Set Mode9 to Free status "MODE 10 Set Mode10 to Free status Details Delete the data registered in Custom Mode1-10 and returns it to Free status. This command operates the same way as storing to Mode1-10 in PC Adjust Menu. (Available only in the normal Power ON status) Response Acceptable Unacceptable "000" [CR] "101" [CR] --- When input is Video signal --- When input is no signal 31/105

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60
  • 61
  • 62
  • 63
  • 64
  • 65
  • 66
  • 67
  • 68
  • 69
  • 70
  • 71
  • 72
  • 73
  • 74
  • 75
  • 76
  • 77
  • 78
  • 79
  • 80
  • 81
  • 82
  • 83
  • 84
  • 85
  • 86
  • 87
  • 88
  • 89
  • 90
  • 91
  • 92
  • 93
  • 94
  • 95
  • 96
  • 97
  • 98
  • 99
  • 100
  • 101
  • 102
  • 103
  • 104
  • 105

PLC-HF10000L
Expand Serial Command Functional Specifications
31/105
8.5.9 CF_PCSTORE Command
Command
“CF_PCSTORE_%1” [CR]
%1
“MODE1” --------------------------- Store current PC Adjust status to Mode1
“MODE2” --------------------------- Store current PC Adjust status to Mode2
“MODE3” --------------------------- Store current PC Adjust status to Mode3
“MODE4” --------------------------- Store current PC Adjust status to Mode4
“MODE5” --------------------------- Store current PC Adjust status to Mode5
“MODE6” --------------------------- Store current PC Adjust status to Mode6
“MODE7” --------------------------- Store current PC Adjust status to Mode7
“MODE8” --------------------------- Store current PC Adjust status to Mode8
“MODE9” --------------------------- Store current PC Adjust status to Mode9
“MODE10” ------------------------- Store current PC Adjust status to Mode10
Details
Store current value of PC Adjust (each parameter status such as Total dots) to
Mode1-10. This command operates the same way as storing to Mode1-10 in PC
Adjust Menu.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“101” [CR] --- When input is Video signal
--- When input is no signal
8.5.10 CF_PCMODEFREE Command
Command
“CF_PCMODEFREE_%1” [CR]
%1
“MODE1” --------------------------- Set Mode1 to Free status
“MODE 2” --------------------------- Set Mode2 to Free status
“MODE 3” --------------------------- Set Mode3 to Free status
“MODE 4” --------------------------- Set Mode4 to Free status
“MODE 5” --------------------------- Set Mode5 to Free status
“MODE 6” --------------------------- Set Mode6 to Free status
“MODE 7” --------------------------- Set Mode7 to Free status
“MODE 8” --------------------------- Set Mode8 to Free status
“MODE 9” --------------------------- Set Mode9 to Free status
“MODE 10” ------------------------- Set Mode10 to Free status
Details
Delete the data registered in Custom Mode1–10 and returns it to Free status.
This
command operates the same way as storing to Mode1-10 in PC Adjust Menu.
(Available only in the normal Power ON status)
Acceptable
“000” [CR]
Response
Unacceptable
“101” [CR] --- When input is Video signal
--- When input is no signal